Optimization procedure (optional): 
 
 
Gather velocity versus time data while issuing an open loop command (i.e. #4O25) 
   
 
Increase  the  slip  gain  gradually  (small  increments~0.00001)  until  you  reach  a  satisfactory  rise 
time. Of course, the time constant of the motor should not be violated. 
 
Slip Gain Optimization, Experimental Data: 
 
 
 
Note 
High  slip  gain  values  can  cause  the  motor  to  hunt  and  lose 
smoothness. 
 
Correcting I2T Settings 
The motor continuous current limit has to be corrected for the optimized Ixx77 
I458=INT((I469*I469-I457*I457+I477*I477)*ServoClk*1000*I2TOnTime/(32767*32767))  
 
Closed-Loop vs. Open-Loop Operation 
AC induction motors with encoder can be commanded to run in either open-loop mode (i.e. #nO25) at a 
pre-defined base speed or closed-loop mode at various programmable speeds (e.g. rigid tapping).