Trane Gas Unit Heaters Wartungshandbuch

Seite von 43
GHND-SVX01C-EN
33 
Maintenance
Periodic Service
All Maintenance/Service information should be recorded 
accordingly on the inspection sheet provided in this 
manual (see 
).
Note: The heater and vent system should be checked 
once a year by a qualified technician.
Important:
Gas tightness of the safety shut-off valves 
must be checked on at least an annual basis.
To check gas tightness of the safety shut-off valves, turn off 
the manual valve upstream of the appliance combination 
control. Remove the 1/8-inch pipe plug on the inlet side of 
the combination control and connect a manometer to that 
tapping. Turn the manual valve on to apply pressure to the 
combination control. Note the pressure reading on the 
manometer, then turn the valve off. A loss of pressure 
indicates a leak. If a leak is detected, use a soap solution to 
check all threaded connections. If no leak is found, 
combination control is faulty and must be replaced before 
putting appliance back in service.
Should maintenance be required, perform the following 
inspection and service routine:
1.
Inspect the area near the unit to be sure that there is no 
combustible material located within the minimum 
clearance requirements listed in this manual.
2. Turn off the manual gas valve and electrical power to 
the gas unit heater.
3. To clean or replace the main burners, remove the 
bottom panel and compress the spring by moving the 
burner toward the manifold. Slide the opposite end of 
the burner downward from the locating slot while 
retaining spring is still compressed. Pull the burners 
away from the heat.
4. With the burners removed, wire brush the inside 
surfaces of the heat exchanger.
5. Remove any dirt, dust, or other foreign matter from the 
burners using a wire brush and/or compressed air. 
Ensure that all parts are unobstructed. Inspect and 
clean pilot burner if necessary.
6. Reassemble the gas unit heater by replacing all parts in 
reverse order.
7.
Complete the appropriate unit start-up procedure as 
given in 
 (see lighting instruction 
plate ).
8. Check the burner adjustment (see 
9. Check all gas control valves and pipe connections for 
leaks.
10. Check the operation of the automatic gas valve by 
lowering the setting of the thermostat, stopping the 
operation of the gas unit heater. The gas valve should 
close tightly, completely extinguishing the flame on 
the main burners.
11. Inspect and service the motor/fan assemblies. To 
maintain efficient air flow, inspect and clean the fan 
blades and guard to prevent buildup of foreign matter.
WARNING
Hazardous Service Procedures!
The maintenance and troubleshooting procedures 
recommended in this section of the manual could 
result in exposure to electrical, mechanical or other 
potential safety hazards. Always refer to the safety 
warnings provided throughout this manual concerning 
these procedures. When possible, disconnect all 
electrical power including remote disconnect and 
discharge all energy storing devices such as capacitors 
before servicing. Follow proper lockout/tagout 
procedures to ensure the power can not be 
inadvertently energized. When necessary to work with 
live electrical components, have a qualified licensed 
electrician or other individual who has been trained in 
handling live electrical components perform these 
tasks. Failure to follow all of the recommended safety 
warnings provided, could result in death or serious 
injury.
WARNING
Hazardous Voltage and Gas!
Turn off the gas supply and disconnect all electric 
power, including remote disconnects before servicing 
unit. Follow proper lockout/tagout procedures to 
ensure the power can not be inadvertently energized 
and the gas can not be inadvertently turned on. Failure 
to turn off gas or disconnect power before servicing 
could result in death or serious injury.
WARNING
Hazard of Explosion!
Never use an open flame to detect gas leaks. Explosive 
conditions may occur. Use a leak test solution or other 
approved methods for leak testing. Failure to follow 
recommended safe leak test procedures could result in 
death or serious injury or equipment or property-only-
damage.
WARNING
Combustible Materials!
Maintain proper clearance between the unit heat 
exchanger, vent surfaces and combustible materials. 
Refer to unit nameplate and installation instructions for 
proper clearances. Improper clearances could result in a 
fire hazard. Failure to maintain proper clearances could 
result in death or serious injury or property damage.