GE RAK6052 Installationsanweisungen

Seite von 4
STEP 1 (continued)
3. Drill two 7/32
″ dia. holes into each end of the
case for attachment of the mounting plates. 
A template is provided in these instructions.
Mounting plates should be mounted before
installing the case in the wall opening.
4. Attach the mounting plates to the case with four
unpainted slotted screws provided. Secure on the
inside of the case with speed clips provided.
5. If necessary, transfer end cap to the opposite end
of the adapter. The end cap is attached to the end
NOT used for attaching extension duct RAK601.
6. Separate the transition duct from the lateral duct
adapter by removing the two thumb screws.
Carefully slide the transition duct forward and off
of the lateral duct adapter.
Holes 2 places
left and right end
16
9
1
16
11
2
Case
(end view)
Mounting hole
position
7/32
11/16
STEP 2
Adjust the discharge grille or damper
1. Check louvered discharge grille section. Louvers
should point away from the wall and toward the
room. If necessary, remove this grille section and
turn 180
°; reassemble.
2. The air discharge damper on top of the lateral
duct adapter can be changed for primary and
secondary room air distribution.
NOTE:
The discharge damper is factory installed to
provide approximately 35% air discharge into the
primary room (room in which the unit is installed)
and 65% into the secondary (adjacent) room. To
increase the amount of air discharged into the
primary room, the damper may be modified by
removing the discharge grille on top of the adapter
and cutting off the scored section of damper to
provide approximately a 50/50 split. Completely
removing the discharge damper will result in
approximately 75% air discharge into the primary
room and 25% into the secondary room.
3. Attach the duct adapter to the case mounting
plates with the four painted 5/16
″ hex head
screws provided.
Case
Speed clips
Mounting
plate
Mounting
plate
Discharge damper
Discharge grille
Thumb
screws
End
cap
Open
end
Lateral
duct
adapter
Mounting
plate
Discharge grille
and damper
Discharge damper
Cut here for
50/50 split
Lateral duct adapter
Transition duct