GE RAK6052 Installationsanweisungen

Seite von 4
STEP 3
Chassis modification and installation
1. Remove the room cabinet front by pulling out at
the bottom to release it. Lift it up to clear the rail
along the chassis top.
2. Slide the chassis into the case and secure with
the four screws through the chassis flange holes.
3. Test fit seals as described below before removing
paper backing.
4. Remove paper backing from each seal and place
as shown. Seal at right side should be located
towards left side of metal flange. It should be
flush with the top rear and extend over the lower
edge of flange. Seal at left side should be located
towards the right side of the metal flange. It
should be flush with the top rear and extend over
the lower edge of flange (as shown in illustration).
Be sure both seals are pressed into place on the
metal flanges (seals should be as close as
possible to screen without overlapping onto it).
5. Remove and save the three screws holding the
front of the air discharge screen in place. Align
the metal seal strip in place as shown and secure
with the three screws. Center the strip and snug
the screws. 
6. Remove the seven screws that hold the louver
section in place and remove it.
7. Reconnect power and check operation.
8. Reinstall the room cabinet front by hooking the
top over the rail along the chassis top. Push it in
at the bottom.
9. Slide the transition duct into place under the
adapter and secure it with the two thumb screws.
1
2
Wall case
Transition duct
1
2
Louver screws
Louver screws
Foam gasket
Metal seal strip