Installation
800937
12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Step 4: (Gas Dryer Only) Connect Gas 
Supply Pipe
For further assistance, refer to section on Gas 
Requirements
.
1. Make certain dryer is equipped for use with the 
type of gas in laundry room. Dryer is equipped at 
the factory for Natural Gas with a 3/8 in. N.P.T. 
gas connection.
2. Remove the shipping cap from the gas 
connection at the rear of the dryer. Make sure you 
do not damage the pipe threads when removing 
the cap.
3. Connect to gas supply pipe using a new flexible 
stainless steel connector.
4. Tighten all connections securely. Turn on gas and 
check all pipe connections (internal and external) 
for gas leaks with a non-corrosive leak detection 
fluid. 
5. For L.P. (Liquefied Petroleum) gas connection, 
refer to section on Gas Requirements.
Figure 11 
D434I
1
New Stainless Steel Flexible Connector – 
Use only if allowed by local codes 
(Use Design A.G.A. Certified Connector)
4
Black Iron Pipe
Shorter than 20' (6.1 m) – Use 3/8" pipe
Longer than 20' (6.1 m) – Use 1/2" pipe
2
1/8" N.P.T. Pipe Plug 
(For checking inlet gas pressure)
5
3/8" N.P.T. Gas Connection
3
Equipment Shut-Off Valve – Installed within 
6' (1.8 m) of dryer
1
5
4
2
3