Alliance Laundry Systems SWD439C User Manual

Page of 76
Installation
13
800937
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Step 5: (Electric Dryer Only) Connect 
Electrical Plug
For further assistance, refer to section on Electrical 
Requirements
.
IMPORTANT:  Use only a new U.L. listed No. 10 
(copper wire only) three conductor power supply 
cord kit rated 240 Volts (minimum) 30 Amperes 
and labeled as suitable for use in a clothes dryer.
Figure 12 
NOTE: For more detailed information on 
connecting three-wire or four-wire plugs, refer to 
section on Electric Dryer Electrical Requirements
.
NOTE: Four-wire cord is required for mobile 
homes or where codes do not permit grounding 
through neutral.
Figure 13 
D275I
D006I
1
Typical Receptacle
2
Power Cord (Not supplied with dryer)
3
Strain Relief Nut
4
Strain Relief
1
2
3
4
THREE-WIRE
1
2
3
4
FOUR-WIRE
D679I
D680I
NOTE: Dryer is shown with access cover removed for 
illustration purposes only. NEVER operate the dryer 
with access cover removed.
1
Ground Wire
2
Ground to Neutral Wire
3
Neutral Terminal
4
“L2” Terminal
5
Center Wire (Neutral)
6
Strain Relief (Not supplied with dryer)
7
Ground Screw
8
“L1” Terminal
9
Black Wire
10
White Wire (Neutral)
11
Red Wire
D679I
1
8
7
6
5
4
3
2
THREE-WIRE CONNECTION
D680I
1
8
7
6
10
4
3
1
11
9
FOUR-WIRE CONNECTION