Whirlpool W10150626A User Manual

Page of 48
6
Dryer Dimensions
*Most installations require a minimum 5" (12.7 cm) clearance 
behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this 
dryer. This dryer has been tested for spacing of 0" (0 cm) 
clearance on the sides and rear. Recommended spacing should 
be considered for the following reasons:
Additional spacing should be considered for ease of 
installation and servicing.
Additional clearances might be required for wall, door and 
floor moldings.
Additional spacing should be considered on all sides of the 
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.
Companion appliance spacing should also be considered. 
Additional spacing is required if you exhaust out the rear of 
the dryer to either the right or left side.
*Required spacing
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The 
installation must conform to the Manufactured Home 
Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction 
and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 
MH.
Mobile home installations require:
Metal exhaust system hardware, which is available for 
purchase from your dealer.
Mobile home Installation Kit Part Number 346764. See “Tools 
and Parts” section for information on ordering.
Special provisions must be made in mobile homes to 
introduce outside air into the dryer. The opening (such as a 
nearby window) should be at least twice as large as the dryer 
exhaust opening.
Electrical Requirements
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical 
supply is required. A time-delay fuse or circuit breaker is 
recommended. It is also recommended that a separate circuit 
serving only this dryer be provided.
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
43 ½"
(110.5 cm)
*29 ¼"
(74.3 cm)
22¼"
(56.5 cm)
29"
(73.7 cm)
A
B
C
    18"*
(45.7 cm)
   1" 
(2.5 cm)
       29"
(73.7 cm)
        1"
(2.5 cm)
        1"*
     (2.5 cm)
14" max.*
(35.6
 
cm)
   29¼"
(74.3 cm)
    5"
 (12.7 cm)
  48 in.   * 
(310 cm  )
2
2
  24 in.  *
(155 cm  )
2
2
       3"*
(7.6 cm)
       3"*
(7.6 cm)
       
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
GROUNDING INSTRUCTIONS
SAVE THESE  INSTRUCTIONS
■  
For a grounded, cord-connected dryer: 
This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.
WARNING: 
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative 
or personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with the 
dryer: if it will not fit the outlet, have a proper outlet installed 
by a qualified electrician.