Install vent System
12" min.
(305 mm)
12" min.
(305 mm)
Install exhaust hood
1.
Install exhaust hood and use caulking compound to seal 
exterior wall opening around exhaust hood.
connect vent to exhaust hood
2.
Vent must fit over the exhaust hood. Secure vent to exhaust 
hood with 4" (102 mm) clamp. Run vent to dryer location 
using straightest path possible. Avoid 90° turns. Use clamps 
to seal all joints. Do not use duct tape, screws, or other 
fastening devices that extend into interior of vent to secure 
vent, because they can catch lint.
vent System chart
number of 
90° turns  
or elbows
Type  
of vent
Box/louvered 
hoods
Angled  
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
The “Vent System Chart” provides venting requirements that 
will help achieve best drying performance.
Determine vent length and elbows needed for best 
drying performance:
Use following “Vent System Chart” to determine type of vent 
 
material and hood combinations acceptable to use.
noTE: Do not use vent runs longer than those specified  
in “Vent System Chart.” Exhaust systems longer than those 
specified will:
Shorten life of dryer.
 
Reduce performance, resulting in longer drying times  
 
and increased energy usage.
noTE: Side and bottom exhaust installations have a 90º turn 
inside the dryer. To determine maximum exhaust length, add 
one 90º turn to the chart.
connect vent
connect vent to exhaust outlet
1.
Using a 4" (102 mm) clamp, connect vent to exhaust outlet  
in dryer. If connecting to existing vent, make sure vent is 
clean. Dryer vent must fit over dryer exhaust outlet and inside 
exhaust hood. Check that vent is secured to exhaust hood 
with a 4" (102 mm) clamp.
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible 
portion of the mobile home structure and must not terminate 
beneath the mobile home. Terminate the exhaust vent outside.
 
Determine vent path:
Select route that will provide straightest and most direct  
 
path outdoors.
Plan installation to use fewest number of elbows and turns.
 
When using elbows or making turns, allow as much room  
 
as possible.
Bend vent gradually to avoid kinking.
 
Use as few 90° turns as possible.