Whirlpool W10224594A User Manual

Page of 16
10
2. Connect neutral wire (white or center wire) of power supply cord 
to the center silver-colored terminal screw of the terminal block. 
Tighten screw.
A
B
C
D
E
A. External ground conductor screw
B. Neutral ground wire
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E. ¾" (19 mm) UL listed strain relief
3. Connect the other wires to outer 
terminal block screws. Tighten 
screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into 
slot of dryer rear panel. Secure cover 
with hold-down screw.
6. You have completed your electrical 
connection. Now go to “Venting Requirements.”
3-wire connection: Direct wire
Use where local codes permit 
connecting cabinet-ground 
conductor to neutral wire.
Direct wire cable must have 5 ft 
 
(1.52 m) of extra length so dryer can 
 
be moved if needed. 
Strip 3
1
/
2
" (89 mm) of outer covering 
from end of cable. Strip insulation 
back 1" (25 mm). If using 3-wire cable with ground wire, cut bare 
wire even with outer covering. Shape ends of wires into a hook 
shape.
When connecting to the terminal block, place the hooked 
 
end of the wire under the screw of the terminal block 
(hook facing right), squeeze hooked end together and 
tighten screw, as shown.
 
1. Loosen or remove center silver-colored terminal 
 
block screw.
2. Place the hooked end of the neutral wire (white or center wire) of 
direct wire cable under the center screw of terminal block (hook 
facing right). Squeeze hooked end together. Tighten screw. 
A
C
D
B
E
A. External ground conductor screw
B. Neutral ground wire
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E. ¾" (19 mm) UL listed strain relief
3. Place the hooked ends of the other 
direct wire cable wires under the outer 
terminal block screws (hooks facing 
right). Squeeze hooked ends together. 
Tighten screws.
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into 
slot of dryer rear panel. Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to 
“Venting Requirements.”
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do 
not permit connecting cabinet-ground conductor to neutral wire.
1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor 
screw. Connect neutral ground wire and the neutral wire (white 
 
or center wire) of power supply cord/cable under center, silver-
colored terminal block screw. Tighten screw.
A. External ground conductor 
screw
B. Center silver-colored terminal 
block screw
C.Neutral ground wire
D. Neutral wire
 
 (white or center wire)
E. ¾" (19 mm) UL listed 
 
strain relief
F. Grounding path determined 
by a qualified electrician
A
B
C
D
F
E
    1"
(25 mm)
    3½"
(89 mm)