Whirlpool W10224594A User Manual

Page of 16
12
Exhaust
A and B: Recommended hood styles.
 
C: Acceptable hood style. 
     4"
(102 mm)
      4"
(102 mm)
B
A
   4"
(102 mm)
2½"
(64 mm)
C
A. Louvered hood style
B. Box hood style
C. Angled hood style
An exhaust hood should cap the vent to keep rodents and 
insects from entering the home.
Exhaust hood must be at least 12" (305 mm) from the ground or 
any object that may be in the path of the exhaust (such as 
flowers, rocks or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and lint to collect 
indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper, 
carpets, etc.
Housecleaning problems and health problems.
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer. Other 
installations are possible.
H
G
F
E
D
C
A
B
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left side or 
through the bottom. If you prefer, you may contact your local dealer 
to have the dryer converted.
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death 
or fire.
A
B
C
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for 
your installation. Two close-clearance installations are shown. Refer 
to the manufacturer’s instructions. 
A
B
A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation
NOTE: The following kits for close clearance alternate installations 
are available for purchase. Please see the “Assistance or Service” 
section to order.
Over-the-Top Installation: 
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent 
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch
Part Number 4396011 - 18" (457 mm) to 29" (737 mm) 
mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1.27 m) mismatch