Whirlpool W10300460A User Manual

Page of 16
11
4.  Connect the other wires to outer terminal block screws. 
Tighten screws.
5.  Tighten strain relief screws.
6.  Insert tab of terminal block cover into slot of dryer rear panel. 
Secure cover with hold-down screw. 
7.  Connect a separate copper wire (G) from the external ground 
conductor screw (A) to an adequate ground, as determined by 
a qualified electrician.
A
G
Venting Requirements
WARNING
Fire Hazard
use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death 
or fire.
WARnInG:
 To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
ImPoRTAnT: 
Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,  
chimney, wall, ceiling, attic, crawlspace, or a concealed space  
of a building. 
If using an existing vent system
Clean lint from the entire length of the system and make sure 
 
exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid heavy metal 
 
vent or flexible metal vent.
Review Vent system chart. Modify existing vent system if 
 
necessary to achieve the best drying performance. Only rigid 
or flexible metal vent shall be used for exhausting.
If this is a new vent system
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
 
4" (102 mm) heavy metal exhaust vent and clamps must be 
 
used. DURASAFE™ venting products are recommended.
4" (102 mm) heavy metal exhaust vent
DURASAFE™ vent products can be purchased from your 
dealer or by calling the toll-free number listed on the cover 
of the Dryer User Instructions. For more information, see the 
“Assistance or Service” section of the Dryer User Instructions.
Rigid metal vent:
For best drying performance, rigid metal vents are 
 
recommended.
Rigid metal vent is recommended to avoid crushing and 
 
kinking.
Flexible metal vent: 
Flexible metal vents are acceptable only if accessible for 
 
cleaning.
Flexible metal vent must be fully extended and supported 
 
when the dryer is in its final location.
Remove excess flexible metal vent to avoid sagging 
 
and kinking that may result in reduced airflow and poor 
performance.
Do not install flexible metal vent in enclosed walls, ceilings,  
 
or floors.
The total length of flexible metal vent shall not exceed  
 
7¾ ft. (2.4 m).
Elbows:
45° elbows provide better airflow than 90° elbows.
 
Good
Better