Whirlpool W10300460A User Manual

Page of 16
13
Periscope Installation (For use with dryer vent to wall vent 
 
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch
Part Number 4396011 - 18" (460 mm) to 29" (737 mm) 
mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1270 mm) 
mismatch
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible 
portion of the mobile home structure and must not terminate 
beneath the mobile home. Terminate the exhaust vent outside.
 
Determine vent path:
Select the route that will provide straightest and most direct  
 
path outdoors.
Plan the installation to use the fewest number of elbows and 
 
turns.
When using elbows or making turns, allow as much room  
 
as possible.
Bend vent gradually to avoid kinking.
 
Use as few 90° turns as possible.
 
Determine vent length and elbows needed for  
best drying performance:
Use following Vent system chart to determine the elbow and 
 
hood combinations acceptable to use.
noTE: Do not use vent runs longer than those specified  
in the Vent System Chart. Exhaust systems longer than those 
specified will:
Shorten life of dryer.
 
Reduce performance, resulting in longer drying times    
 
and increased energy usage.
The Vent system chart provides venting requirements that will 
help achieve best drying performance.
Vent System Chart
noTE: Side and bottom exhaust installations have a 90º turn 
inside the dryer. To determine maximum exhaust length, add  
one 90º turn to the chart.
number 
90° turns or 
elbows
Type of vent
Box/louvered 
hoods
Angled hods
0
Rigid metal 64 ft. (20 m)
58 ft. (17.7 m)
1
Rigid metal 54 ft. (16.5 m)
48 ft. (14.6 m)
2
Rigid metal 44 ft. (13.4 m)
38 ft. (11.6 m)
3
Rigid metal 35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid metal 27 ft. (8.2 m)
21 ft. (6.4 m)
Install Vent System
1.  Install exhaust hood. Use caulking compound to seal exterior 
wall opening around exhaust hood.
2.  Connect vent to exhaust hood. Vent must fit inside exhaust 
hood. Secure vent to exhaust hood with 4" (102 mm) clamp.
3.  Run vent to dryer location. Use the straightest path possible. 
See “Determine vent path” in “Plan Vent System.” Avoid 90º 
turns. Use clamps to seal all joints. Do not use duct tape, 
screws, or other fastening devices that extend into the interior 
of the vent to secure vent, because they can catch lint.
level Dryer
Check the levelness of the dryer. Check levelness first side to 
side, then front to back.
If the dryer is not level, prop up the dryer using a wood block. 
Use a wrench to adjust the legs up or down and check again  
for levelness.
noTE: It might be necessary to level the dryer again after it is 
moved into its final position.
Connect Vent
1.  Using a 4" (102 mm) clamp, connect vent to exhaust outlet 
in dryer. If connecting to existing vent, make sure the vent is 
clean. The dryer vent must fit over the dryer exhaust outlet 
and inside the exhaust hood. Check that the vent is secured 
to exhaust hood with a 4" (102 mm) clamp.
2.  Move dryer into its final location. Do not crush or kink vent. 
Make sure dryer is level.
3.  Once the exhaust vent connection is made, remove the 
corner posts and cardboard.