Whirlpool W10240585C-SP User Manual

Page of 32
12
Vent System Chart
Number of 
90° elbows
Type  
of vent
Box/louvered 
hoods
Angled  
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
INSTALL VENT SYSTEM
12" min.
(305 mm)
12" min.
(305 mm)
Install exhaust hood
1.
Install exhaust hood and use caulking compound to seal 
exterior wall opening around exhaust hood.
Connect vent to exhaust hood
2.
Vent must fit over the exhaust hood. Secure vent to exhaust 
hood with 4" (102 mm) clamp. Run vent to dryer location 
using straightest path possible. Avoid 90° turns. Use clamps 
to seal all joints. Do not use duct tape, screws, or other 
fastening devices that extend into interior of vent to secure 
vent, because they can catch lint.
The Vent System Chart provides venting requirements that 
will help achieve best drying performance.
Determine vent path:
Select route that will provide straightest and most direct  
 
path outdoors.
Plan installation to use fewest number of elbows and turns.
 
When using elbows or making turns, allow as much room  
 
as possible.
Bend vent gradually to avoid kinking.
 
Use as few 90° turns as possible.
 
Determine vent length and elbows needed for best 
drying performance:
Use following Vent System Chart to determine type of vent 
 
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified  
in Vent System Chart. Exhaust systems longer than those 
specified will:
Shorten life of dryer.
 
Reduce performance, resulting in longer drying times  
 
and increased energy usage.
NOTE: Side and bottom exhaust installations have a 90° turn 
inside the dryer. To determine maximum exhaust length, add one 
90° turn to the chart.
Prepare dryer for leveling legs
1. 
To avoid damaging floor, use a large flat piece of cardboard 
from dryer carton; place under entire back edge of dryer. 
Firmly grasp dryer body (not console panel) and gently lay 
dryer down on cardboard.
INSTALL LEVELING LEGS
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.