Whirlpool 8578186 User Manual

Page of 44
11
The angled hood style (shown following) is acceptable.
See the exhaust vent length chart that matches your hood 
type for the maximum vent lengths you can use.
Exhaust systems longer than specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and 
increased energy usage.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than those 
specified in the Vent Length Chart.
The following chart helps you determine your maximum vent 
length based on the number of 90° turns or elbows you will 
need and the type of vent (rigid or flexible metal) and hood 
that you will use.
Vent Length Chart
NOTE: Side and bottom exhaust installations have a 90º turn 
inside the dryer. To determine maximum exhaust length, add one 
90º turn to the chart.
Install Vent System
1. (Optional) Put on safety glasses and gloves.
2. Install exhaust hood. Use caulking compound to seal exterior 
wall opening around exhaust hood.
3. Connect vent to exhaust hood. Vent must fit inside exhaust 
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
4. Run vent to dryer location. Use the straightest path possible. 
See “Determine Vent Length.” Avoid 90º turns. Use clamps to 
seal all joints. Do not use duct tape, screws or other fastening 
devices that extend into the interior of the vent to secure 
vent.
Install Leveling Legs
1. To protect the floor, use a large flat piece of cardboard from 
the dryer carton. Place cardboard under the entire back edge 
of the dryer. See illustration.
2. Firmly grasp the body of the dryer (not the console panel). 
Gently lay the dryer on the cardboard.   
3. Examine the leveling legs. Find the diamond marking. 
4. Screw the legs into the leg holes by hand. Use a wrench to 
finish turning the legs until the diamond marking is no longer 
visible.
5. Place a carton corner post under each of the 2 dryer back 
corners. Stand the dryer up. Slide the dryer on the corner 
posts until it is close to its final location. Leave enough room 
to connect the exhaust vent or gas line.
6. Once connection is made and dryer is in final location, 
remove corner posts and cardboard.
For mobile home use
Gas dryers must be securely fastened to the floor at the time of 
installation.
Mobile home installations require a Mobile Home Installation Kit. 
For more information, please reference the service numbers in 
the “Assistance or Service” section of this manual.
Number of 
90º turns 
or elbows
Type of
vent
Box or 
Louvered 
hoods
Angled
hoods
0
Rigid metal
Flexible metal
64 ft (20 m)
36 ft (11 m)
58 ft (17.7 m)
28 ft (8.5 m)
1
Rigid metal
Flexible metal
54 ft (16.5 m) 
31 ft (9.4 m)
48 ft (14.6 m)
23 ft (7 m)
2
Rigid metal
Flexible metal
44 ft (13.4 m)
27 ft (8.2 m)
38 ft (11.6 m)
19 ft (5.8 m)
3
Rigid metal
Flexible metal
35 ft (10.7 m)
25 ft (7.6 m)
29 ft (8.8 m)
17 ft (5.2 m)
4
Rigid metal
Flexible metal
27 ft (8.2 m)
23 ft (7 m)
21 ft (6.4 m)
15 ft (4.6 m)
      4"
(10.2 cm)
    2½"
(6.4 cm)
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.