Whirlpool 8578186 User Manual

Page of 44
9
Burner input requirements
Elevations up to 10,000 ft (3,048 meters):
The design of this dryer is certified by CSA International for 
use at altitudes up to 10,000 ft (3,048 m) above sea level at 
the B.T.U. rating indicated on the model/serial number plate. 
Burner input adjustments are not required when the dryer is 
operated up to this elevation.
Elevations above 10,000 ft (3,048 meters):
When installed above 10,000 ft (3,048 m) a 4% reduction of 
the burner B.T.U. rating shown on the model/serial number 
plate is required for each 1,000 ft (305 m) increase in 
elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping 
system during pressure testing at pressures greater than 
½ psi.
Venting Requirements
WARNING: 
To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
4" (10.2 cm) heavy metal exhaust vent and clamps must be used. 
DURASAFE™ vent products are recommended.
DURASAFE™ vent products can be purchased from your dealer 
or by calling Whirlpool Parts and Accessories. For more 
information, see the “Assistance or Service” section of this 
manual.
The dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling, or a concealed space of a building.
Do not use an exhaust hood with a magnetic latch.
Do not install flexible metal vent in enclosed walls, ceilings or 
floors.
Use clamps to seal all joints. Exhaust vent must not be 
connected or secured with screws or other fastening devices 
which extend into the interior of the duct. Do not use duct 
tape.
IMPORTANT: Observe all governing codes and ordinances.
Use a heavy metal vent. Do not use plastic or metal foil vent.
Rigid metal vent is recommended to prevent crushing and 
kinking.
Flexible metal vent must be fully extended and supported when 
the dryer is in its final position. Remove excess flexible metal vent 
to avoid sagging and kinking that can result in reduced airflow 
and poor performance.
An exhaust hood should cap the vent to prevent rodents and 
insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground or 
any object that is in the path of the exhaust (such as flowers, 
rocks or bushes, etc.).
If using an existing vent system, clean lint from the entire length 
of the system and make sure exhaust hood is not plugged with 
lint. Replace any plastic or metal foil vent with rigid metal or 
flexible metal vent.
Plan Vent System
Typical exhaust installations 
Typical installations vent the dryer from the rear of the dryer. 
Other installations are possible.
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
Improper venting can cause moisture and lint to collect 
indoors, which may result in:
Moisture damage to woodwork, furniture, paint, 
Housecleaning problems and health problems.
  wallpaper, carpets, etc.