Thermo Products CMC1-75DV3N User Manual

Page of 65
All installations and services must be performed by qualified service personnel. 
CMC1-50D36 
ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE 
COOLING UNIT 
HTG Speed 
Recommended CLG Speed 
24,000 
LOW 
MED-LOW  
30,000 
LOW 
MED-HIGH 
36,000 
LOW 
HIGH 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
               
 
 
 
 
 
 
 
 
 
 
 
 
           
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Speed Tap \ 
Static 
Pressure 
Furnace Airflow (CFM) vs. External Static pressure (in. WC.) 
0.1 
0.2 
0.3 
0.4 
0.5 
0.6 
0.7 
Low 
836 
805 
773 
743 
695 
620 
566 
ML 
1044 
1010 
972 
914 
860 
826 
752 
MH 
1250 
1196 
1146 
1101 
1038 
977 
902 
High 
1339 
1338 
1283 
1233 
1162 
1086 
1008 
Speed Tap \ 
Static 
Pressure 
Temperature Rise vs. External Static Pressure (in. WC.) 
0.1 
0.2 
0.3 
0.4 
0.5 
0.6 
0.7 
Low 
53 
55 
57 
59 
63 
71 
78 
ML 
42 
44 
45 
48 
51 
53 
59 
MH 
35 
37 
38 
40 
42 
45 
49 
High 
31 
33 
34 
36 
38 
41 
44 
Speed Tap 
\ Static 
Pressure                             
Blower Motor Current Draw (Amps) vs. External Static pressure (in. WC.) 
0.1 
0.2 
0.3 
0.4 
0.5 
0.6 
0.7 
Low 
3.3 
3.2 
3.1 
3.0 
2.9 
2.7 
2.6 
ML 
4.0 
3.8 
3.6 
3.5 
3.4 
3.2 
3.1 
MH 
4.6 
4.4 
4.2 
4.1 
4.0 
3.8 
3.6 
High 
5.3 
5.1 
5.0 
4.9 
4.7 
4.6 
4.4 
Speed Tap \ 
Static 
Pressure 
Blower Motor Watts vs. External Static pressure (in. WC.) 
0.1 
0.2 
0.3 
0.4 
0.5 
0.6 
0.7 
Low 
315 
311 
304 
300 
292 
281 
275 
ML 
400 
390 
376 
363 
351 
342 
330 
MH 
485 
467 
452 
441 
427 
412 
394 
High 
573 
555 
544 
530 
513 
493 
477 
 
Recommended operation range 
 
36