Thermo Products CMC1-75DV3N User Manual

Page of 65
All installations and services must be performed by qualified service personnel. 
CMC1-50DV3 
ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE 
COOLING UNIT 
HTG Speed 
Recommended CLG Speed 
24,000 
LOW 
MED-LOW  
30,000 
LOW 
MED-HIGH 
36,000 
LOW 
HIGH 
 
 
Speed Tap \ 
Static 
Pressure 
Furnace Airflow (CFM) vs. External Static pressure (in. WC.) 
0.1 
0.2 
0.3 
0.4 
0.5 
0.6 
0.7 
Low 
700 
639 
567 
497 
437 
387 
332 
ML 
876 
834 
781 
725 
653 
602 
556 
MED 
990 
948 
907 
857 
811 
756 
700 
MH 
1174 
1145 
1107 
1066 
1026 
987 
942 
High 
1398 
1365 
1326 
1299 
1265 
1252 
1190 
 
 
               
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
 
 
 
Speed Tap \ 
Static 
Pressure 
Temperature Rise vs. External Static Pressure (in. WC.) 
0.1 
0.2 
0.3 
0.4 
0.5 
0.6 
0.7 
Low 
63 
69 
78 
88 
101 
114 
132 
ML 
50 
53 
56 
61 
67 
73 
79 
MED 
44 
46 
48 
51 
54 
58 
63 
MH 
37 
38 
40 
41 
43 
45 
47 
High 
31 
32 
33 
34 
35 
35 
37 
Speed Tap 
\ Static 
Pressure                             
Blower Motor Current Draw (Amps) vs. External Static pressure (in. WC.) 
0.1 
0.2 
0.3 
0.4 
0.5 
0.6 
0.7 
Low 
1.1 
1.1 
1.2 
1.2 
1.2 
1.3 
1.4 
ML 
1.7 
1.7 
1.8 
1.8 
1.9 
1.9 
2.0 
MED 
2.2 
2.2 
2.3 
2.4 
2.5 
2.5 
2.5 
MH 
3.4 
3.4 
3.4 
3.5 
3.6 
3.6 
3.7 
High 
5.2 
5.2 
5.2 
5.3 
5.3 
5.4 
5.5 
Speed Tap \ 
Static 
Pressure 
Blower Motor Watts vs. External Static pressure (in. WC.) 
0.1 
0.2 
0.3 
0.4 
0.5 
0.6 
0.7 
Low 
72 
77 
81 
84 
87 
91 
95 
ML 
123 
127 
133 
137 
141 
145 
148 
MED 
168 
173 
178 
183 
188 
192 
197 
MH 
266 
272 
277 
284 
290 
296 
301 
High 
438 
442 
445 
450 
455 
461 
468 
 
Recommended operation range 
 
38