CMC1-75D36 
ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE 
COOLING UNIT 
HTG Speed 
Recommended CLG Speed 
24,000 
MED-LOW 
MED-LOW  
30,000 
MED-LOW 
MED-HIGH 
36,000 
MED-LOW 
HIGH 
 
 
Speed Tap \ 
Static 
Pressure 
Furnace Airflow (CFM) vs. External Static pressure (in. WC.) 
0.1 
0.2 
0.3 
0.4 
0.5 
0.6 
0.7 
Low 
817 
797 
773 
730 
668 
620 
555 
ML 
1019 
995 
959 
918 
869 
821 
760 
MH 
1257 
1210 
1174 
1125 
1076 
1024 
959 
High 
1470 
1420 
1366 
1312 
1259 
1196 
1127 
 
 
 
 
 
 
 
 
 
 
 
 
               
Speed Tap \ 
Static 
Pressure                             
Blower Motor Current Draw (Amps) vs. External Static pressure (in. WC.) 
0.1 
0.2 
0.3 
0.4 
0.5 
0.6 
0.7 
Low 
3.1 
3.0 
2.9 
2.8 
2.7 
2.6 
2.5 
ML 
3.9 
3.8 
3.6 
3.5 
3.3 
3.2 
3.1 
MH 
4.8 
4.6 
4.4 
4.2 
4.1 
4.0 
3.8 
High 
5.7 
5.5 
5.4 
5.2 
5.1 
5.0 
4.8 
 
 
Speed Tap \ 
Static 
Pressure 
Blower Motor Watts vs. External Static pressure (in. WC.) 
0.1 
0.2 
0.3 
0.4 
0.5 
0.6 
0.7 
Low 
312 
303 
298 
291 
280 
273 
264 
ML 
400 
390 
381 
366 
354 
342 
330 
MH 
513 
490 
478 
462 
447 
432 
413 
High 
624 
605 
591 
573 
556 
542 
522 
 
 
 
 
 
 
           
 
 
Speed Tap \ 
Static 
Pressure 
Temperature Rise vs. External Static Pressure (in. WC.) 
0.1 
0.2 
0.3 
0.4 
0.5 
0.6 
0.7 
Low 
81 
83 
85 
90 
90 
106 
119 
ML 
65 
66 
69 
72 
76 
80 
87 
MH 
52 
55 
56 
59 
61 
64 
69 
High 
45 
46 
48 
50 
52 
55 
59 
 
Recommended operation range 
 