To determine how each control operates the UA-90H, it must 
first be determined which control is being used and whether 
or not the 90H is ducted for fresh air ventilation. Refer to 
appropriate section. 
Humidity/Fan Control Panel (P/N 4024155) (Figure 1, p.7) 
4.6A   
  Humidity/Fan Control Panel WITHOUT Fresh Air   
Ventilation or Damper  
4.6B   
 Humidity/Fan Control Panel WITH Fresh Air   
Ventilation and WITHOUT Damper  
4.6C   
 Humidity/Fan Control Panel WITH Fresh Air  
Ventilation AND Damper  
Ventilation Timer/Humidity Control Panel (P/N 4024125)  
(Figure 2, p.7) 
4.6D  
 Ventilation Timer and Humidity Control WITH Fresh Air 
AND Motorized Damper 
DEH 2000 Digital Control (P/N 4024539) (Figure 1, p.10) 
4.6E  
Digital Controller WITH Fresh Air AND Damper 
4.6F  
Digital Controller WITHOUT Fresh Air 
4.6A Humidity/Fan Control Panel WITHOUT Fresh Air 
Ventilation or Damper 
The humidity/fan control panel automatically controls the humidity 
of the living space. The humidity/fan control panel contains an 
adjustable humidity control and a fan switch. The panel has a 
cover that must remain open to the air within the living space for 
accurate humidity sensing. When the fan switch is in the “ON” 
position, air will be continually filtered and circulated throughout 
the home. For humidity control operation refer to section 4.7. 
4.6B Humidity/Fan Control Panel WITH Fresh Air 
Ventilation and WITHOUT Damper 
The humidity/fan control panel automatically controls the humidity 
of the living space. The humidity/fan control panel contains an 
adjustable humidity control and a fan switch. The panel has a 
cover that must remain open to the air within the living space for 
accurate humidity sensing. Outside air is continually introduced 
whenever fan is “ON.” Manual operation of fan filter switch controls 
outside air ventilation. Since the fan operates whenever the UA-90H 
is dehumidifying outside air will also be introduced. For humidity 
control operation refer to section 4.7. 
4.6C Humidity/Fan Control Panel WITH Fresh Air 
Ventilation AND Damper 
In this configuration, a motorized damper has been installed 
in the fresh air duct. When the fan/filter switch is in the “OFF” 
position, the damper is closed. The UA-90H will then circulate and 
dehumidify air to provide humidity control. 
When the fan/filter switch is in the “ON” position, the motorized 
damper will open and the fan will run, introducing outside air. The 
unit may or may not be dehumidifying in the ventilation mode, 
depending on the humidity control setting. See Section 4.7 for 
humidity control operation. 
4.6D Ventilation Timer and Humidity Control WITH 
Fresh Air AND Motorized Damper 
Refer to sections 4.7 through 4.9C. 
4.6E DEH 2000 Digital Control WITH Fresh Air AND 
Damper 
Refer to Section 5. 
4.6F DEH 2000 Digital Control WITHOUT Fresh Air 
Refer to Section 5. 
4.7 Humidity Control Adjustment 
Set the humidity control to the desired 
humidity level for the home. Turning the knob 
clockwise results in a drier setting. See the 
back of the control panel cover for set points. 
The dehumidifier will run continuously until 
the relative humidity (RH) is reduced to the 
humidity control dial setting. Setting the 
humidity control to lower RH levels will NOT 
increase the dehumidification rate; the unit will 
simply run longer to reduce the RH to the setting. The UA-90H unit 
(and refrigerant-based dehumidifiers in general) will reduce a warm 
space’s RH to a lower level than that of a cool space. Therefore 
there is no benefit to set the humidity control to excessively 
low levels in cool rooms; doing so will result in long periods of 
ineffective dehumidifier run time. Settings below 45% are not 
recommended. 
4.8 Fan/Filter Switch 
Turning ON the fan/filter switch will cause the 
UA-90H fan to run continuously, whether the 
UA-90H is dehumidifying or not. This function 
is desirable if the unit is used for air circulation 
and filtration to achieve maximum indoor air 
quality. When the switch is ON; air will be 
constantly filtered through the UA-90H and 
circulated throughout the house. When the 
switch is OFF the fan will operate only when the humidity control 
calls for dehumidification or when the ventilation timer calls for 
ventilation. 
FOR HVAC INSTALLER AND HOMEOWNER
Figure 3
Humidity Control 
Adjustment Knob
Figure 4
Fan/Filter Switch
8
Ultra-Aire 90H Installer’s & Owner’s Manual
9
Ultra-Aire 90H Installer’s & Owner’s Manual