4.9 Ventilation Timer 
The ventilation timer controls the fan and the motorized fresh 
air damper. When the ventilation timer is activated, the UA-90H 
will circulate the indoor air, and bring in fresh air from outside. 
The ventilation timer should be set for the required ventilation 
of the residence. The home should be ventilated with fresh air 
as suggested by applicable codes and standards or as required 
by the homeowner. The ventilation timer is an electronic timer 
that displays the current time. This timer has battery backup, 
so it will not require resetting after a power outage. Following 
a prolonged power outage the display of the timer will flash on 
and off indicating a power outage has occurred. The one-minute 
time increments of the ventilation timer allow you to program the 
ventilation of your home to fit your schedule. 
The ventilation timer allows six programs with each program 
having one “ON” and one “OFF” event. A program allows the 
user to turn the ventilation on at a certain day and time, then it 
allows them to turn the ventilation off at a certain day and time. 
Each of these programs can be repeated daily or weekly or 
during a specified block of days. All six of the programs operate 
independently of each other. If the timer fails to operate or operates 
erratically, check that the control panel receives 24Vac from the 
UA-90H. If 24Vac is present at the control panel, reset the timer by 
pressing the reset button at the bottom center of the timer face. 
The reset button is the small recessed button with an R beneath 
it located below the 1-7 and h buttons. Depress the reset button 
until the display clears. Release the reset button. The display will 
reappear as 00:00. Resetting the timer will clear the time and all 
program settings. After resetting the timer follow the instructions 
below to set the correct time and ventilation programs. 
4.9A Setting the Time 
Set the correct time on the timer by sliding the switch in the upper 
right hand corner of the timer to the clock symbol. and pressing the 
1-7 (DAY), h (HOUR), and m (MINUTE) buttons. Remember this timer 
operates on a 24-hour (military time) clock. 
4.9B Ventilation Schedule 
Slide the switch in the upper right hand corner to the program 
symbol P. “ON” will appear to the right of the time and the number 
“1” will appear in the lower right hand corner of the display. The 
“1” and “ON” signify the turn on time for the first program. Press 
the 1-7, h and m button to choose the days of the week for this 
program. You can choose Mon.-Sun., Mon.-Fri., Sat.-Sun., or any 
single day of the week. The days chosen are shown along the top 
of the display on the ventilation timer. Next press the h button to 
set the hour for the start of the ventilation period. Remember this 
timer operates on a 24-hour clock (military time). Then press the m 
button to set the minutes past the hour to start the ventilation. 
Now, with the ventilation start time set; press the I/O button. The 
word “OFF” should appear to the right of the time and the number 
“1” should remain in the lower right hand corner of the display. The 
“1” and “OFF” signify the turn off time for the first program. Set 
the turn off time using the 1-7, h and m buttons in the same way 
as described above and continue on to the second through sixth 
programs. When setting the ventilation programs, you can return 
to the current time display by sliding the switch in the upper right 
corner of the timer to RUN. The slide switch must be set to RUN for 
the timer to operate its scheduled programs. 
4.9C Automatic or Manual Mode 
The slide switch in the upper left of the timer is used to choose 
between automatic and manual operation. When the slide switch 
is set to AUTO mode, the UA-90H will ventilate when the scheduled 
programs call for ventilation. When the slide switch is set to manual 
(set to hand symbol on the right), the operation of the timer is 
controlled by the I/O button only. Pressing the I/O button will switch 
the ventilation timer between ON (detent) and OFF (detent). As you 
press the I/O button, “ON” or “OFF” will be displayed to the right of 
the time. The “ON” or “OFF” indicates if the ventilation timer is on 
or off. The I/O button will manually override scheduled programs if 
the timer is in AUTO mode. 