Monessen Hearth HDV500NV/PV User Manual

Page of 64
56D3048
1
HDV Series Direct Vent Gas Fireplace
VeNtING INStAllAtIoN 
W
ARNING
you  may  use  a  reducer  from  5"  x  8" 
to 4" x 6
B\," for horizontal with vertical 
rise  application.  oNly  use  framing 
instructions below when using 4" x 6
B\,
venting. 
If the reducer is installed at the rear of 
the  unit,  you  must  immediately  follow 
with a 90° elbow for a vertical rise before 
continuing with any horizontal run.
1.  Locate and cut the vent opening in the wall. For com-
bustible walls first frame in opening. 
  Combustible  Interior  Walls:  Cut  a  11Z\x"H  x  9Z\x"  W 
hole through the interior wall.
  Combustible  exterior  Walls:  Cut  a  9Z\x"H  x  9Z\x"W 
square hole through the exterior wall frame. Figure 26  
  Noncombustible Walls:Hole opening should be 7Z\x" 
(190 mm) in diameter.
.  The center of the hole should line up with the center line 
of the horizontal rigid vent pipe end. Allow 
1
/4" minimum 
rise per foot. Figure 26
Note: #1222DA reducer must be used when 4 x 6B\,
venting is preferred. Reducer must be installed directly 
onto unit at pipe adaptor before vertical rise. 
VO584-100
Vent Opening
2/99   djt
Figure 26 - 
Exterior Wall Framing Dimensions for 4 x 6
B\," Venting  
9Z\x"
(41 mm)
9Z\x"
(41 mm)
Combustible Wall
Framing
VO584-100
7Z\x" 
(190 mm)
Noncombustible Wall
BeloW GRADe INStAllAtIoNS
When it is not possible to meet the required vent terminal 
clearances of 1" above grade level, a snorkel kit is recom-
mended. It allows installation depth down to 7" (178 mm) 
below grade level. The 7" (178 mm) is measured from the 
center of the horizontal vent pipe as it penetrates through 
the wall.
ensure the sidewall venting clearances are observed. 
If venting system is installed below ground, we recom-
mend a window well with adequate and proper drainage 
to be installed around the termination area.
If installing a snorkel, a minimum 4" vertical rise is neces-
sary. The maximum horizontal run with the 4” vertical pipe 
is 36". This measurement is taken from the collar of the 
fireplace (or transition elbow) to the face of the exterior wall. 
See the Sidewall Venting Graph for extended horizontal 
run if the vertical exceeds 4".
1.  Establish vent hole through the wall. Page 17, Figure 
16
.  Remove soil to a depth of approximately 16" below base 
of snorkel. Install drain pipe. Install window well (not 
supplied). Refill hole with 1" of coarse gravel leaving 
a clearance of approximately 4" below snorkel. Figure 
27
3.  Install vent system.
4.  Ensure a watertight seal is made around the vent pipe 
coming through the wall.
5.  Apply  high  temperature  sealant  caulking  (supplied) 
around the 5" and 8" snorkel collars.
6.  Slide the snorkel into the vent pipes and secure to the 
wall.
7.  Level the soil so as to maintain a 4" clearance below 
snorkel. Figure 27
FP1965
below grade install
24”
Minimum
Figure 27 -  
Below Grade Installation
Screws
Minimum 
4" Clearance
Ground
Window 
Well 
Gravel 
Drain 
Foundation Wall 
Firestop 
FP1965