Monessen Hearth BWBC500MHB User Manual

Page of 40
61D0087 
21
OUTSIDE COMBUSTION AIR
Fireplaces in 
manufactured homes 
must be supplied with 
outside combustion air. 
W
ARNING
These fireplaces are provided with model AK6A combustion air kit (for floor 
installation only) to supply outside combustion air to the fireplace. 
If outside wall installation or ceiling/soffit installation is preferred, pur-
chase model AK6 combustion air kit from fireplace dealer. See Figure 10, 
page 12. 
PRECAUTION AND RECOMMENDATIONS 
1.   Avoid extremely long runs and numerous turns in the flex duct leading from 
the fireplace to the air inlet assembly. These conditions will increase the 
resistance to the free flow of air through the flex duct.
2.   Locate air inlet assembly  where it will not be blocked or restricted in 
any manner.
3.   Never mount the combustion air inlet assembly in a garage or storage area where combustible fumes such as gasoline 
might be drawn into the fireplace. Do not take combustion air from any area where combustible liquids or gases are 
stored.
4.   Carefully  cut  holes  for  the  installation  of  the  combustion  air  kit. You  must  maintain  the  structural  integrity of 
the home.
Maintain the structural 
integrity of the 
manufactured home 
floor, wall, and ceiling/
roof.
CAUTION 
Figure 21 - Attaching Outside Air Starting Collar and 
Insulation Ring to Left Side of Fireplace 
Starting 
Collar 
Sheet 
Meal 
Screws 
Left Side of Fireplace 
Shorter End of Air 
Starting Collar 
INSTALLATION OF  
AK6A COMBUSTION AIR KIT 
1.   Remove the cover plate from the combustion air 
inlet on left side of the fireplace.
2.   Place the starting collar into the hole on the side 
of the fireplace. Fasten collar in place with four 
(4) sheet metal screws as specified by Figure 
21.
3.   Cut a 6½" diameter hole in floor leading into a 
ventilated crawl space and install the air inlet 
assembly. See Figure 22
Locate the air inlet assembly 
where it will not be blocked or 
restricted in any manner. The 
air  inlet  assembly  must  not 
terminate in an attic space. 
W
ARNING
4.   Use duct straps to secure flex duct to starting 
collar and inlet air assembly. See Figure 22
Note:  If it is necessary to splice the flex duct, 
use  Model  603  duct  connector  and 
Model FP-6-U combustion air duct.
Figure 22 - Securing Flex Duct to Starting Collar and 
Inlet Air Assembly with Duct Straps 
Left Side of 
Fireplace 
Flex Duct 
(6" Dia.)
Ventilated Crawl Space 
Air Inlet 
Assembly 
Duct 
Strap