Monessen Hearth BWBC500MHB User Manual

Page of 40
61D0087 
23
Fan
Motor
1
Fan
Motor
2
On/Off
Rocker Switch 
(SPST)
Cord Set
120V, 60Hz
Fireplace
Receptacle Box 
Ground 
Field Wire to
60Hz, 120 VAC, 15AMP
Electrical Circuit 
12"max. 
A
B
This fireplace is equipped with a fan assembly to help circulate heat pro-
duced by the fireplace. The energy used by the fan assembly will be less 
than a 30 watt light bulb.
The fan assembly has been factory-wired to the fireplace receptacle box 
located on the right side of the fireplace. Connect wiring from the fireplace 
receptacle box (field-wired) to a 60 Hz, 120 vac, 15 amp electrical circuit. 
Field-wiring must comply with local codes or, in the absence of local 
codes, with the latest edition of National Electrical Code ANSI/NFPA 70. 
See Figure 26. 
Always  check  and  make 
sure  power  is  off  before 
attempting  to  install  or 
service any electrical wiring 
or components. 
W
ARNING
Figure 26 - Wiring Diagram 
Figure 25 - Locating Mantel 
LOCATING MANTEL 
Maximum depth of mantel is 12"
A =  6½"  -  Minimum from top of fireplace opening to bottom 
of any combustible trim material sticking out no 
more than 1½" beyond face of fireplace 
B =  12" -  Minimum from top of fireplace opening to bottom 
of combustible trim material sticking out more than 
1½" from top of fireplace opening
Top of 
Fireplace 
Opening 
Combustible 
Mantel
 Non-
Combustible 
Surround Trim 
FAN ASSEMBLY 
TRIM AND MANTEL INSTALLATION FOR WOOD BURNING FIREPLACES 
Combustible 
Wall Board