Monessen Hearth BWBC500MHB User Manual

Page of 40
22 
61D0087
TRIM AND MANTEL INSTALLATION FOR WOOD BURNING FIREPLACES 
•  The fireplace face may be left exposed or trimmed with 
material such as brick, stone, or marble. If trim is installed, 
fasten it securely to face of fireplace. Seal any cracks 
between trim material and face of fireplace. Cracks can 
cause a fire and prevent fireplace from working properly. 
Block the fireplace with framing and attach the base to the 
supporting floor to reduce the possibility of such a crack 
developing. 
•  Place wall ties in mortar joints of masonry trim. Fasten 
wall ties to face of fireplace with sheet metal screws. 
•  Do not install combustible materials below the top spac-
ers of the fireplace. Do not allow combustible materials to 
overlap the sides of fireplace face. Seal face of fireplace 
to surrounding wall with noncombustible caulk or trim 
materials. This will prevent cold air leaking around the 
fireplace. See Figure 23. 
•  Use only non-combustible materials below top of spac-
ers. 
•  The trim must not block or restrict in any way the flow of 
air through the air inlet and air outlet louvers in the face 
of the fireplace. 
Seal  any  space  between  face  of 
fireplace and non-combustible facing 
material. Failure to seal this crack is a 
possible fire hazard and will void the 
warranty. 
W
ARNING
¾" 
Separation 
0" Clearance 
to Front Side 
Walls 
LOCATING FRONT AND SIDE CLEARANCES 
To find front clearances, extend a line from back corner of unit 
to 4" in front of fireplace face and 1" outside screened opening. 
Combustible materials may be placed within shaded areas. 
Note: Do not let combustible materials overlap black 
painted surface more than 
1
/
8
". 
See Figure 24.
Trim may butt against side walls of fireplace. The other 3 walls 
must have ¾" clearances. 
To avoid interference with glass doors, do not allow non-
combustible decorative trim to extend closer than 
3
/
8
" to the 
vertical edges of the firebox opening.
4" Reference 
Extended Line 
1" Reference 
Figure 23 - Spacer Location 
Figure 24 - Front and Side Clearances 
Combustible Material 
within Shaded Area 
Combustible 
Wallboard  
Non-Combustible 
Trim 
Area to Be 
Sealed 
Do not block or restrict air inlets or 
air outlets. Blocking or restricting air  
inlets or air outlets could cause a fire 
hazard. 
W
ARNING