Monessen Hearth LX36DV User Manual

Page of 48
18
51D0528
LX Series Direct Vent Gas Fireplace
VeNtING INStALLAtIoN
HOT
FP2715
horiz cap w shield
Figure 17 - 
Installing Horizontal Vent Cap 
Vent Cap
Apply Mastic to 
All Four Sides 
Deflecting Shield 
Wood Screw
FP2715
For vinyl siding, stucco, or wood exterior use vinyl siding 
standoffs  between  vent  cap  and  exterior  wall. The  vinyl 
siding standoff prevents excessive heat from melting the 
vinyl siding material. Bolt the vent cap to the standoff. Apply 
non-hardening mastic around outside edge of the standoff 
instead of the vent cap assembly. Use wood screws pro-
vided to attach the standoff. Figure 18
HOT
Fp2716
vinyl siding standoff
Figure 18 - 
Install Vinyl Siding Standoff 
Apply Mastic to 
All Four Sides 
Cut Vinyl Siding Away 
to Fit Standoff 
Wood Screw
Vent 
Cap
Screw 
Standoff 
Deflecting Shield 
FP2716
FP1957
install firestop
Figure 19 - 
Connect Vent Cap with Horizontal Vent Pipe 
Interior Wall 
Surface 
Fire Stop 
Assembly 
Horizontal 
Vent Pipe 
Screw
Vent Cap 
(Horizontal 
Termination)
FP1957
hoRIZoNtAL (thRouGh the WALL) teR-
MINAtIoN coNFIGuRAtIoNS
Since it is very important that the venting system main-
tain its balance between the combustion air intake and 
the flue gas exhaust, certain limitations as to vent con-
figurations apply and must be strictly adhered to.
The Vent Graph, showing the relationship between vertical 
and horizontal side wall venting, will help to determine the 
various dimensions allowable. Refer to Page 16 
Minimum clearance between vent pipes and combus-
tible  materials  is  3"  on  top  and  1"  from  bottom  and 
sides unless otherwise noted.
When vent termination exits through foundations less than 
20" below siding outcrop, the vent pipe must flush up with 
the siding.
It is best to locate the fireplace in such a way that minimizes 
the number of offsets and horizontal vent length.
W
ARNING
When  installing  the  appliance  as  a  rear 
vent  unit,  the  90°,  45°  transition  elbow 
attached directly to the rear of the unit is 
Not  INcLuDeD  in  the  following  criteria 
and  calculations,  and  unless  specifically 
mentioned  should  be  ignored  when 
calculating venting layouts.
The horizontal vent run refers to the total length of vent 
pipe from the flue collar of the fireplace (or the top of the 
Transition Elbow) to the face of the outer wall.
   The  maximum  number  of  90°  elbows  per  side  wall 
installation is three (3). Figure 20
   If a 90° elbow is fitted directly on top of the fireplace 
flange the maximum horizontal vent run before the ter-
mination or a vertical rise is 36” (914 mm). Figure 21
   If a 90° elbow is used in the horizontal vent run (level 
height maintained) the horizontal vent length is reduced 
by 36" (914 mm). This does not apply if the 90° elbows 
are used to increase or redirect a vertical rise. Figure 
23
5.  Slide fire stop over the vent pipe before connecting the 
horizontal run to the vent cap. Figure 19
6.  The pipe overlap should be a minimum of 1Z\v". Apply 
silicone to the outer pipe connection. Fasten all vent 
connections with screws provided.
7.  Slide fire stop against the interior wall surface and attach 
with screws. Figure 19