Monessen Hearth 624DV(ST User Manual

Page of 52
42D0200
Designer Series Gas Fireplaces
17
REaR waLL vENT INSTaLLaTIoN 
When installed as a rear vent unit this appliance may be vented directly to a termination located on 
the rear wall behind the appliance
   The maximum horizontal distance between the rear of the appliance and the outside face of the 
rear wall is 20" (508 m). Figure 16
   Only one 45° elbow is allowed in these installations.
vENTING INSTaLLaTIoN     
1.  Locate  and  cut  the  vent  opening  in  the  wall.  For 
combustible walls first frame in opening.  
 
Combustible  walls:  Cut  a  11Z\x"H  x  9Z\x"  W  (292  x 
241 mm) hole through the exterior wall and frame as 
shown. Figure 17
  Noncombustible walls: Hole opening should be 7Z\x" 
(190 mm) in diameter.
2.  Rigid  vent  pipes  and  fittings  have  special  twist-lock 
connections. Assemble  the  desired  combination  of 
pipe and elbows to the appliance adaptor with pipe 
seams oriented towards the wall or floor.
  Twist-lock Procedure: The female ends of the pipes 
and  fittings  have  three  locking  lugs  (indentations). 
These lugs will slide straight into matching slots on 
the male end of adjacent pipes and fittings. Push the 
pipe sections together and twist one section clockwise 
approximately one-quarter turn until the sections are 
fully locked. Figure 18
3.  Attach vent pipe assembly to the fireplace. Set fire-
place in front of its permanent location to insure mini-
mum clearances. Mark the wall for a 11Z\x"H x 9Z\x"W 
(292 x 241 mm) rectangle hole (for noncombustible 
material such as masonry block or concrete, a 7Z\x" 
[190  mm]  diameter  hole  is  acceptable).  Figure  17. 
The center of the hole should line up with the center 
line of the horizontal rigid vent pipe end. Be sure to 
allow for minimum rise. Cut a 11Z\x"x9Z\x" rectangle hole 
through combustible exterior wall (7Z\x" diameter hole 
if  noncombustible).  Frame  as  necessary. Allow  1/4" 
minimum rise per foot. Figure 17
Figure 16 - 
Rear Vent Application, Maximum 
Horizontal Distance 
Top View Flat 
Installation
Figure 17 - 
Vent Opening Requirements 
FP1954
wall framing
9Z\x"
(241 mm)
11Z\x"
(292 mm)
7Z\x"
(190 mm)
FP1954
NoTE: Horizontal runs of vent must 
be  supported  every  three  (3)  feet 
(914  mm).  Use  wall  straps  for  this 
purpose. 
Figure 18 - 
Rigid Vent Pipe Connections
Female Locking 
Lugs 
Male Slots
FP1953
rigid pipe
FP1953
DVR584-600
Rear vent no elbows
2/99   djt
20"
(508 mm)