Monessen Hearth 624DV(ST User Manual

Page of 52
18
42D0200
Designer Series Gas Fireplaces
vENTING INSTaLLaTIoN 
4.  Apply a bead of non-hardening mastic around the outside 
edge  of  vent  cap.  Position  the  vent  cap  in  the  center  of  
hole on the exterior wall with the word “UP” on the vent cap 
facing up. Insure proper clearance of 1" to combustibles 
is maintained. Attach the vent cap with four wood screws 
supplied. Figure 19
NoTE: Replace the wood screws with appropriate fasteners 
for stucco, brick, concrete, or other types of siding. 
For  vinyl  siding,  stucco,  or  wood  exterior  use  vinyl  siding 
standoffs between vent cap and exterior wall. The vinyl siding 
standoff prevents excessive heat from melting the vinyl siding 
material. Bolt the vent cap to the standoff. Apply non-harden-
ing mastic around outside edge of the standoff instead of the 
vent cap assembly. Use wood screws provided to attach the 
standoff. Figure 20
5.  Slide fire stop over the vent pipe before connecting hori-
zontal run to vent cap. Figure 21
6.  Insert vent pipe into the horizontal termination. The pipe 
overlap should be a minimum of 1Z\v". Fasten all vent con-
nections with screws provided.
7.  Slide  fire  stop  against  the  interior  wall  surface  and 
attach with screws. Figure 21
REaR waLL vENT INSTaLLaTIoN 
(continued)
HOT
FP1956
vinyl siding standoff
Figure 20 - 
Installing Vinyl Siding Standoff 
Apply 
Mastic to All 
Four Sides 
Cut Vinyl Siding Away 
to Fit Standoff 
Wood Screw
Vent Cap
Bolt
Nut
Standoff 
Deflecting 
Shield 
w
a
RNING
do not recess vent termination into any wall. 
This will cause a fire hazard.
HOT
FP1955
horizontal vent cap
Figure 19 - 
Installing Horizontal Vent Cap
 
Vent Cap
Wood Screw
Apply Mastic to 
All Four Sides 
Deflecting 
Shield 
FP1955
FP1956
FP1957
install firestop
Figure 21 - 
Connecting Vent Cap with Horizontal Vent Pipe
 
Interior Wall 
Surface 
Horizontal 
Vent Pipe 
Screw
Vent Cap 
(Horizontal 
Termination)
FP1957