WDV Series Gas Fireplace
V
G
G=6" (152mm)
F
F=6" (152mm)
V
V
G
G = Combustible 24"(610mm)
 
Noncombustible 18"(457mm)
Combustible & 
Noncombustible
H = 24" (610mm)
J =  20" (508mm)
V
H
J
C = Maximum depth of 48" (1219mm)
    for alcove location
D = Minimum width for back wall of
    alcove location
    Combustible - 38" (965mm)
    Noncombustible - 24" (610mm)
E = Clearance from corner in alcove 
    location
    Combustible - 6" (152mm)
    Noncombustible - 2" (51mm)
E
V
D
C
C
Inside Corner 
Alcove Location
Outside Corner 
Balcony with No Side Wall
Balcony with Perpendicular
Side Wall
FP1951
termination clearances
VentInG InstallatIOn 
terMInatIOn clearances FOr BuIlDInGs WIth cOMBustIBle  
anD nOncOMBustIBle exterIOrs 
Figure 9 - 
Allowable Venting Chart 
hOW tO use the Vent Graph
The  Vent  Graph  should  be  read  in  conjunction  with  the 
following  vent  installation  instructions  to  determine  the 
relationship between the vertical and horizontal dimensions 
of the vent system.
1.  Determine the height of the center of the horizontal vent 
pipe exiting through the outer wall. Using this dimen-
sion on the Sidewall Vent Graph below, locate the point 
intersecting with the slanted graph line.
2.  From the point of this intersection, draw a vertical line 
to the bottom of the graph.
3.  Select the indicated dimension, and position the fire-
place in accordance with same.
  Example: If the vertical dimension from the floor of the 
fireplace is 11' (3.4 m) the horizontal run to the face of 
the outer wall must not exceed 16' (4.9 m).
Sidewall  Vent  Graph  showing  the  relationship  between 
vertical and horizontal dimensions for a Direct Vent flue 
system.
Combustible – 6" (152 mm) 
Noncombustible – 2" (51 mm)
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
2  4  6  8 10 12 14 16 18 20
eg: A
FP2132
sidewall vent graph
Figure 10 - 
Rear Wall Venting Graph
Horizontal dimension from the finished outside 
wall to the center of the pipe on the fireplace
V
ertical Dimension From the Floor of Unit to the 
Center of the Horizontal V
ent Pipe
Dimensions in Feet
50"
From Floor to 
Center