1.  Remove  the  cover  plate  from  the  4”  outlet  opening 
location on the left outside of the fireplace.
2.  Place starting collar (4”) into hole on left side of fire-
place.  Fireplace  shortest  side  of  air  starting  collar 
through fireplace outer wrap. Fasten starting collar in 
place with four (4) sheet metal screws provided. Fig-
ure 11
NOTE:  The  air  starting  collar  extends  through  the 
fireplace outer wrap. When the air starting collar is 
securely attached, it will form a seal against the fire-
place wall.
3.  Cut  a  6”  diameter  opening  for  model  OAC-4  in  the 
outside wall covering where the outside vent is to be 
located. Figure 13
4.  Select and cut a piece of duct long enough to attach 
to the fireplace and stick out at least 3” beyond the 
face of the wall to which the OAC-4 inlet air vent will 
be  attached.  Cut  duct  with  a  standard  pocket  knife. 
Figure 12
W
ARNING
DO  NOT  remove  the  cover 
if the outside air will not be 
connected.
W
ARNING
Do not use a combustible duct. Always use 
UL Listed Class 0 or 1 duct material. If nec-
essary  to  splice  duct,  use  Model  403  duct 
connector to splice duct sections.
&0
ATTACH
Left Side of 
Fireplace
OAC-4 
Starting 
Collar
Sheet Metal 
Screws
Shorter End of Air 
Starting Collar
FP2023
Figure 11 - 
Attach Outside Air Starting Collar to Left Side of 
Fireplace
&0
ATTACH
Air Starting Collar
Screws
Screws
Duct
Left Side of 
Fireplace
FP2024
Figure 12 -
 Attach Outside duct to Starting Collar
&0
COMB
6” Diameter 
Hole
Duct Ex-
tending 3” 
Min.
AK-4 Inlet Air 
Vent
Nail 
Hole
Screws
FP2025
Figure 13 - 
Combustion Air Assembly for Model No. OAC-4
5.  If using insulating duct, push the insulation back from 
one end of the duct approximately 2”. Figure 13
6.  Slip the exposed end of the duct over the starting col-
lar on the fireplace.
7.  Using  the  sheet  metal  screws  provided,  secure  the 
duct end to the collar attached to the fireplace.
8.  Nail or screw the combustion air assembly to the sur-
face of the wall.