624WBPF Woodburning Fireplace
53D9052
Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc., that 
might  complicate  the  installation  or  endanger  persons  installing  or  cleaning  the  chimney. Avoid 
a location where the chimney cap will be near abrupt changes in the roof shape, nearby wall or 
embankments, under or near trees or above the roof of a single story wing of a two story building. 
Figure 6. All these conditions can cause turbulence or pressure conditions that can cause poor 
chimney draft and smoke spillage from the fireplace opening. Elbows may be used to offset the 
chimney to avoid obstructions or to locate the chimney cap in a preferred location. Refer to the 
sections of this manual pertaining to chimney offsets for instructions on proper elbow usage. Poor 
installation or location of the chimney cap and/or components can cause wind blown rain to enter 
the chimney.
If the fireplace is to be installed on an outside wall, the surrounding walls (chase) should be insu-
lated. Failure to insulate the fireplace from outside temperatures will cause heat loss through and 
around the fireplace.
iNStallatioN PreParatioN
14’ Min.
FP2347
single story install
Chimney Cap
Single Story installation with attic Space
Storm Collar
Flashing 
Flue Outlet Height
3’ Min. or 2’ Above 
any Point within 10’
See Table 
1 for Roof 
Opening Size
Attic Space
Firestop Spacer 
(1Z\x” Air space 
Clearance to 
Combustibles)
Chimney 
Sections
17” Square 
Opening in 
Joist
FP2347
Figure 4
2” Min. Air Space 
Clearance Between 
Combustibles and 
Chimney
FP1882
chimney location 
8/08
Preferred 
Location
Poor 
Location
FP1882
Figure 6
3 ft. Min. 
FP2348
multistory install
Multiple Story installation
Chimney Cap
Storm Collar 
(Included with 
cap)
Flashing
Refer to Table 
1 for Roof 
Opening Size
Attic Space
Firestop 
Spacer (2” 
Air Space 
Clearance to 
Combustibles)
2” Clearance to 
Combustibles (Min.)
17” Square Open-
ing in Joist
Max. instal-
lation height 
86 ft.
Support re-
quired every 
35 ft.
Third Floor 
Area
Second 
Floor Area
First Floor 
Area
Flue Outlet Height
17” Square 
Opening in 
Joist
17” Square 
Opening in Joist
Firestop 
Spacer 
Firestop 
Spacer 
FP2348
Figure 5