Hearth & Home Technologies CL36D User Manual

Page of 32
02-02
25
12538 Rev D
CL36D AND CR36D INSTALLATION INSTRUCTIONS
Note:
  Save and pass this instruction manual to subsequent home owners. The informa-
tion provided is intended to notify and warn them about making unsafe future modifications
such as the addition of shelves or the use of unauthorized parts and repairs.
WARNING!
DO  NOT  operate  this  fireplace  with  the  flue
damper  in  the  closed  position.  Combustion
products must vent up the chimney system to
prevent  carbon  monoxide  poisoning,  and  to
prevent hot combustion gases from contacting
and overheating combustible surfaces. Failure
to operate this fireplace with the damper in the
open position may result in asphyxiation or a
structure fire.
CAUTION:
Fireplace operation does require air. Do not take
air from other fuel burning appliances which can
result in improper venting (smoking) or air dilu-
tion. Always provide adequate makeup air.
H. OPERATING INSTRUCTIONS
1. General Information
This  fireplace  is  intended  to  operate  as  a
supplemental heat source for a single room. It is not
designed to function as a primary heat source for a
structure.
Fireplaces, as well as other woodburning appliances,
have  been  used  safely  for  many  years.  It  has  been
our  experience  that  most  problems  are  caused  by
improper  installation  and  operation  of  the  fireplace.
Make  certain  that  installation  and  operation  of  the
fireplace  system  is  in  accordance  with  these
instructions.
It  is  extremely  important  that  the  fire  be  supervised
whenever  the  fireplace  is  in  use.  It  is  also
recommended  that  an  annual  inspection  be
performed on the fireplace system to determine if the
flue system needs to be cleaned, or as in the case of
any  appliance,  if  minor  repairs  are  required  to
maintain the system in top operating condition.
This factory built fireplace is intended for use with either
solid fuel (firewood) or a decorative gas appliance that
has  been  tested  and  listed  to  the  Standard  for
Decorative  Gas  Appliances  for  Installation  in
Vented  Fireplaces, ANSI  Z21.60.  When  operating
your fireplace, the flue damper must be in the open
position.
This fireplace was not tested and listed for use with an
unvented gas log heater. Do not install an unvented
gas log heater in this fireplace and operate it with the
flue  damper  in  the  closed  position  unless  the
unvented gas log heater has been specifically tested
and  listed  for  use  in  this  fireplace  by  Underwriters
Laboratories  Inc.
Use of an unvented gas log heater in this factory
built  fireplace  may  create  a  fire  hazard  that  can
result in a structure fire.
2. Outside Air
A  source  of  air  (oxygen)  is  required  in  order  for
combustion to take place. Whatever air is consumed
by  the  fire  must  be  replaced  through  cracks  around
windows,  under  doors,  etc.  Most  newly  constructed
houses  or  existing  homes  fitted  with  tightly  sealed
doors and windows are relatively air tight. In this case,
an outside air source must be made available to feed
combustion  air  from  outside  the  home.
A damper control handle allows the individual control
of  the  outside  air  inlet  if  your  fireplace  is  equipped
with this option. Use of outside air for combustion is
highly  recommended  to  conserve  heated  air  within
the structure and to provide make up air to keep the
fireplace venting properly.
This  fireplace  will  operate  correctly  only  if  adequate
ventilation  is  provided  to  allow  proper  draft  to  the
fireplace system. Hearth Technologies Inc. assumes
no responsibility for the improper performance of the
fireplace  system  caused  by  inadequate  draft  due  to
environmental  conditions,  down  drafts,  tight  sealing
construction  of  the  structure,  or  mechanical
exhausting  devices  which  create  a  negative  air
pressure  within  the  structure  where  the  fireplace  is
located.
3. Flue Damper
The flue damper must be in a full open position, and
is operated by moving the handle up toward the top
of the fireplace. Before lighting the fire, verify this by
looking  up  from  the  inside  of  the  fireplace. Always
operate  this  fireplace  with  the  damper  fully  open.
Please  note:  down  drafts,  obstructions,  damaged  or
poor  (wet)  fuels  can  cause  smoke  spillage.