Hearth & Home Technologies 5100-I User Manual

Page of 24
5100-I  WOOD INSERT
Page 10
January 30, 2004
R
250-1960  Rev B
MASONRY FIREPLACE 
USING DIRECT-CONNECT METHOD
Refer to: Clearances to Combustibles on page 5,  Canadian Installation requirements on page 12,  
Hearth Requirements on page 5 and Zero Clearance Adjustable Support Kit on page 16.
Figure 10A - Installation Into Masonry Fireplace 
Direct Connect 
  Seal Option
Minimum Starter
   
 Pipe Option
Full Listed 
Liner Option
Masonry Chimney
Flue Tile 
Mantel
Air-tight Face Seal
Damper Area
SEAL DAMPER AREA OR FACE SEAL
INSTALLATION OPTIONS
The Quadra-Fire 5100-I Insert conforms with the UL Stan-
dard for Safety 1482 and ULC S628 (Canada) in all respects, 
and is approved to UL & ULC safety standards for installa-
tion and use within a fireplace with a masonry chimney in 
accordance with NFPA No. 211, with or without a direct flue 
collar connection.  A starter pipe is required to reach to the 
bottom of the existing flue. 
1.  Secure the fireplace damper in the open position.  If this 
cannot be accomplished, it will be necessary to remove the 
damper.
2.   Seal  either  the  damper  area  around  the  chimney  liner 
with a high temperature sealant or the fireplace front with 
fiberglass batting.
3.  The chimney should be examined for cracks, loose mortar, 
and  other  signs  of  deterioration  and  blockage.   The  insert 
should not be installed until it is determined that the chim-
ney is safe for use.  Since an oversized flue contributes to 
the accumulation of creosote, the size of the flue should be 
checked to determine that it is not too large for the insert.  
The chimney should also be checked to ensure it meets the 
minimum standard of the National Fire Protection Associa-
tion (NFPA) Standard 211.  The following bullets list the more 
critical requirements for a properly constructed chimney:
  •  The  masonry  wall  of  the  chimney,  if  brick  or  modular 
block,  must  be  a  minimum  of  4  inches  (102mm)  nominal 
thickness.  A chimney of rubble stone must be at least 12 
inches (305mm) thick
   The chimney must have a fire clay flue liner (or equiva-
lent) with a minimum thickness of 5/8” (16mm) and must be 
installed with refractory mortar.  An equivalent liner must be 
a listed chimney liner system or other approved material.
   A chimney inside the house must have at least 2 inches 
(51mm) of clearance to the combustible structure.  A chim-
ney  outside  the  house  must  have  at  least  1  inch  (25mm) 
clearance to the combustible structure.  Non-combustible fire 
stops  must  be  installed  at  the  spaces  where  the  chimney 
passes through floors and/or ceiling (See Figure 8A and 8B 
on page 8)
NOTE:  In Canada, a full reline is required.
METAL HEAT CIRCULATING MASONRY
The  Quadra-Fire  5100-I  Insert  conforms  with  the  safety 
standard UL-1482 and ULC S628 (Canada) in all respects 
and is approved to UL & ULC safety standards for instal-
lation and use within a fireplace with masonry chimney, in 
accordance with NFPA No. 211, with or without a direct flue 
collar  connection.   A  starter  pipe  is  required  into  existing 
chimney.
 Figure 10
B - 
Installation Into Metal Heat Circulating
Showing Use Of Starter Pipe
Listed Liner 
Mantel 
SEAL DAMPER AREA OR FACE SEAL