Hearth & Home Technologies 5100-I User Manual

Page of 24
Page 9
 
January 30, 2004
5100-I  WOOD INSERT
R
250-1960  Rev B
1.     An outside air inlet must be provided for combustion and must 
remain clear of leaves, debris, ice and/or snow.  It must be 
unrestricted while unit is in use to prevent room air starvation 
which can cause smoke spillage and an inability to maintain a 
fire.  Smoke spillage can also set off smoke alarms.
2.     Unit must be secured to the mobile home structure.   Remove 
bolts from each side of insert and use plumbers tape to secure 
to structure (a washer may be required). Reinstall bolts.  
3.     Unit must be grounded with #8 solid copper grounding wire or 
equivalent and terminated at each end with N.E.C. approved 
grounding device.
4.     The  factory-built  fireplace  must  meet  (UM)84-HUD 
requirements for outside combustion air supply to the firepalce 
fire  chamber  and  the  chimney  must  be  listed  to  UL103-HT 
or a listed UL-1777 full length 6 inch (152mm) diameter liner 
must be used. It must be equipped with a spark arrestor cap 
and  the  outside  air  must  be  installed  on  the  insert. (See  Figure  9A  and  complete  installation  instructions 
of page 13.)  
5.     Refer  to  page  5  of  this  manual  or  the  Serial  label  located  on  the  right  side  of  the  insert  for  clearances  to 
combustibles.
6.     Floor protections requirements on page 5 must be followed precisely.
7.     Use silicone to create an effective vapor barrier at the location were the chimney or other component penetrates 
to the exterior of the structure.
8.     Follow  the  chimney  and  chimney  connector  manufacturer’s  instructions  when  installing  the  flue  system  for  use 
in a mobile home.
INSTALLATIONS INTO ZERO CLEARANCE FIREPLACES IN MOBILE HOMES 
(IN USA ONLY)
WARNING: NEVER DRAW COMBUSTION AIR FROM A WALL, 
FLOOR  OR  CEILING  CAVITY  OR  FROM  ANY  ENCLOSED 
SPACE SUCH AS AN ATTIC OR GARAGE.
CAUTION:   THE STRUCTURAL INTEGRITY OF THE MOBILE 
HOME  FLOOR,  WALL  AND  CEILING/ROOF  MUST  BE 
MAINTAINED. (i.e., DO NOT CUT THROUGH FLOOR JOIST, 
WALL STUD, CEILING TRUSS, ETC.)
WARNING: DO NOT INSTALL IN SLEEPING ROOM.
NOTE:  Offsets from the vertical, not exceeding 45°, are allowed per Section 905(a) of the Uniform Mechanical Code 
(UMC).  Offsets greater than 45° are considered horizontal and are also allowed, providing the horizontal run does 
not exceed 75% of the vertical height of the vent.  Construction, clearance and termination must be in compliance 
with the UMC Table 9C.  This installation must also complies with NFPA 211.
NOTE:   Top  sections  of  chimney  must  be  removable  to  allow  maximum  clearance  of  13.5’ (405cm)  from  ground  level 
for transportation purposes.
9.     Burn wood only.  Other types of fuels may generate poisonous gases (e.g., carbon monoxide).
Figure 9A - Installing Outside Air
Remove 2 Spring Handles
Cover from rear of 
stove  is  secured 
to front of stove
See  complete 
instructions  on 
page 13
Spark Arestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
Double Wall 
Connector Pipe