Dansons Group Inc.
 
AcuTron Wiring  Harness
Air Intake
Vacuum Switch
Low Limit L120
High Limit L250
Fan Limit F140
Combustion Fan
Exhaust
A
UTOMATIC 
S
AFETY 
F
EATURES
 
 
L250 HIGH LIMIT SWITCH 
Your pellet appliance has a high temperature limit switch installed.  If the temperature at the back of the firebox 
reaches approximately 250deg F., the switch will shut off the electricity going to the Vacuum Switch and to the 
Auger Motor.  The auger will automatically stop, and the appliance will shut down when the exhaust temperature 
cools (120deg F).  If this happens call your dealer or Dansons Customer Service (1-866-456-9269).  
 IT IS IMPORTANT TO FIND THE REASON WHY THE UNIT OVERHEATED
 
L120 LOW LIMIT SWITCH 
This limit switch is mounted on the exhaust blower housing and has 2 main functions.  
1.  Should the fire happen to go out, for any reason, this limit switch will shut the stove off when the exhaust 
temperature drops below 120deg F. 
2.  Upon starting the appliance, the AcuTron control board has a 15 minute “Lighting Mode”, if the stove 
exhaust does not reach 120deg F in that 15 minutes the stove will shut off.  As soon as the stove exhaust 
does reach 120deg F, the limit switch opens and the AcuTron enters a 5 minute “Safety Delay” mode. 
 
F140 FAN LIMIT SWITCH 
Your pellet appliance has a convection fan control limit switch.  The room air fan's (F140) temperature limit snap 
switch automatically sets the fan on high when your stove is producing heat faster than the fan is carrying it into the 
room.  This may occur when the heat control lever is set at [3 or 4] and the FAN SPEED is set to a very low or off 
setting.  After the fan runs at this 
automatic high setting a few minutes, 
it may cycle back to its lower setting 
and may continue to cycle between 
[HIGH] and your selected setting.  
The circulation (room air) fan cycling 
from high to low is a normal condition 
as well as a safety feature of your 
appliance. To compensate for the fan 
cycling, adjust the FAN SPEED to a 
higher setting. 
 
VACUUM SWITCH 
This safety device (mounted on the 
back panel pillar) detects vacuum in 
the exhaust system, firebox, and air 
intake.  If the exhaust blower fails, the 
vent pipe becomes plugged, the 
viewing door is open, or if you are out 
of pellets, this switch will sense that 
there is no airflow and will stop the 
auger from continuing to feed pellets. 
 
If the power does go out, the pellet appliance will stop running.  When the power comes back on, 
the stove will not restart if the switch is in the manual mode.   If the exhaust temperature is above 
120deg F or the switch is in the manual position, the stove will start to feed pellets again and may 
re-light itself. 
 
NOTE:  If power outages are a concern you may wish to purchase a battery back-up system.  It must state “For 
Igniter Equipped Appliance” 
and be a minimum of 750 watts. 
 
For further information contact your local Specialty Retailer, Certified HVAC Service Depot, or Dansons 