69-1700
Exiting Installer Setup
1. Press Done key to exit Installer Setup screen.
IMPORTANT
The three Installer Setup Menus (Tables 4-6) 
show all available options. These options cus-
tomize themselves as you make selections to 
Installer Setup. So not all Installer Setup 
Selections are shown or are available to 
change.
Table 4. Main Installer Setup Menu.
Select
Installer 
Setup 
Number
Factory Setting
Other Choices
Comments
Option
Description
Options
Description
Not used.
1 thru 0099 —
 —
Date (Year 
Upper)
0120
20
Set first two digits of 
current calendar 
year (20 for year 
2005, etc)
21
21 —first two digits of 
current calendar year (21xx)
2000 -2178 
available
Date (Year 
Lower)
0130
04
Represents last two 
digits of current 
calendar year 
(2004).
00 -99
Select last two digits of 
current calendar year.
2001-2178 
available
Date (Month) 0140
6
Digit(s) represents 
current calendar 
month.
1-12
Select number that 
represents current calendar 
month.
 —
Date 
(Day)
0150
15
Digit(s) represents 
current calendar 
date.
1-31
Select number that 
represents current calendar 
date.
Schedule 
Options
0160
4
7-day programming 0
0 —nonprogrammable 
 —
System Type 
Selection
0170
1
1 Heat/1 Cool 
Conventional 
System
1-6
1—1 heat/1 cool
2—single-stage heat pump 
(no aux. heat)
3—heat only (no fan)
4 —heat only (with fan)
5—hot water Series 20 
(3-wire or normally open 
zone valves)
6—cool only
Available options 
and defaults vary 
by thermostat. 
System selection 
automatically 
modifies some 
default settings 
and/or hides other 
Installer Setup 
options.
Fan Operation  0180
0
Conventional 
applications where 
equipment controls 
fan operation in 
heat mode.
1
Heat pump or electric heat 
applications where 
thermostat controls fan 
operation in heat mode.
Only shown if 
conventional 
system is 
selected. If heat 
pump is chosen, 
fan defaults to 
electric.
Reversing 
Valve (O/B) 
Operation
0190
0
O/B terminal is 
energized for 
reversing valve in 
cooling
1
O/B terminal is energized for 
reversing valve in heating
Only shown if 
heat pump 
system is chosen.