Honeywell TH8110U User Manual

Page of 12
TH8110U TOUCH SCREEN PROGRAMMABLE THERMOSTATS
9
69-1700
Table 5. Regional Settings Menu.
Select
Installer 
Setup 
Number
Factory Setting
Other Choices
Comments
Option
Description
Options
Description
Changeover
0300
0
Manual changeover
1
1—auto 
changeover
 —
Deadband
0310
3
Heating and cooling 
setpoints can be set 
no closer than 3
°
(1.5
°
C)
2 thru 9
Heating and 
cooling setpoints 
can be set no 
closer  than  
chosen       value:                                                                                    
2—2
°
F (1
°
C)                                                                    
3—3
°
F (2
°
C)                                                                    
4—4
°
F (2.5
°
C)                                                                 
5—5
°
F (3
°
C)                                                            
6—6
°
F (3.5
°
C)                                                                  
7—7
°
F (4
°
C)                                                                   
8—8
°
F (4.5
°
C)                                                           
9—9
°
F (5
°
C)
Shown only if 
automatic 
changeover is 
selected.
Temperature 
Indication 
Scale
0320
0
Temperature is 
displayed in 
°
F.
1
Temperature is 
displayed in 
°
C.
 —
Daylight 
Savings
0330
1
Daylight savings 
enabled (United 
States).
0
0—daylight savings 
is disabled.
Set to 0 in areas that 
do not follow 
daylight savings.
Remote 
Temperature 
Sensor 
(Outdoor or 
Indoor)
0340
0
No remote 
temperature sensor
1,3
1—outdoor 
temperature sensor 
for display only.
3—indoor 
temperature sensor
Defaults and 
Options depend on 
System Type 
selected. Indoor 
Temperature Sensor 
uses an averaging 
network and does 
not include on-board 
sensor.