Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1556
SW-CTL (Switch Control) 
9
Table 9-591.
TEST #92 Control Channel Interface Test 
Error 
Code
Test 
Result
Description/ Recommendation
1338
ABORT
The test is not allowed to run since a planned SPE interchange is in progress. 
This may be caused by a planned interchange initiated automatically during 24 
hour scheduled testing. 
1. Wait 3 minutes and retry the command. 
1339
ABORT
The test could not run on the standby Switch Control on the MSSNET circuit 
pack in the standby SPE carrier because the standby SPE is unavailable. 
1. Refer to the STBY-SPE maintenance documentation for information on why 
a standby SPE may be unavailable and what repair actions should be 
taken. The screen for the status spe command should indicate that 
handshake is down. This may be caused by a variety of reasons such as 
the SPE-SELECT switches on the DUPINT circuit packs being set to the 
position of the active SPE, a failure of the DUPINT circuit pack, or loss of 
power on the standby SPE. The 
SPE Selected field on the status spe 
screen will display 
spe a or spe b if both SPE-SELECT switches are in the a 
or b positions, respectively.
2000
ABORT
Response to the test request was not received within the allowable time period. 
If the system is equipped with the High Reliability or Critical Reliability 
Configuration and if the MSSNET circuit pack is on the standby SPE, this abort 
code may indicate that the standby SPE is not responding to the handshake 
message. If this is the case, the standby SPE maintenance software may take 
up to two minutes to indicate that handshake communication with the standby 
SPE is down. The ABORT code will then change to 1339 (standby SPE 
unavailable). 
1. Retry the command at 1-minute intervals, a maximum of 3 times.
2012 
2500
ABORT
Internal System Error 
1. Retry the command.
2100 
none
ABORT
Could not allocate the necessary system resources to run this test. 
1. Retry the command at 1-minute intervals a maximum of 3 retries. 
2334
ABORT
The hardware mailbox in the standby Duplication Interface circuit pack is not 
ready to receive messages. 
1. Retry the command at 1-minute intervals for a maximum of 5 times. 
Continued on next page