LED Interpretation 
7-3
Circuit Pack LEDs 
7
Circuit Pack LEDs
Each circuit pack typically has three LEDs on the front panel visible at the front of 
the carrier, there are some exceptions to this (for example DS1CONV circuit 
pack) that are covered later in this section. On most circuit packs, the LEDs 
indicate the following when lit. Exceptions to these indications are explained in 
subsequent sections.
LED Alarms without Alarm Log Entry or with
Error Type 1
Whenever the system or a part of the system is reset, all affected circuit packs 
will briefly light their red and green LEDs as they are initialized. Upon power-up of 
a newly installed system, several alarm indicators may remain lit until the circuit 
packs are administered. These alarms should be ignored until administration is 
completed.
During routine or demand testing of Mass Storage System components, the red, 
green and yellow LEDs on the MSSNET, TAPE, and DISK circuit packs all light 
temporarily. This is normal and does not indicate a problem.
After a circuit pack has been initialized, a lit red LED should be accompanied by 
an alarm in the Alarm Log. A single fault can sometimes light alarm LEDs on 
several circuit packs, as in the following examples.
A TDM bus problem may cause several port circuit packs to display red 
LEDS.
An EPN Maintenance circuit pack can prevent an Expansion Interface 
circuit pack from initializing.
Extensive interactions in the Center Stage Switch can cause multiple 
alarms from single faults in DS1C, SNI and SNC circuit packs and fiber 
links.
Tone/clock problems may cause other circuit packs to report alarms.
Red
Alarm
The system has detected a fault in this circuit pack. 
The Alarm Log should contain an on-board alarm for 
this circuit pack or one of the maintenance objects 
associated with it. The red LED is also lit briefly when a 
circuit pack is inserted or reset. If the circuit pack 
passes its initialization tests, the LED is extinguished. If 
a fault is detected, it remains lit.
Green
Testing
The system is currently running tests on this circuit 
pack as part of background maintenance or demand 
testing. This LED is also lit briefly during initialization 
tests when a circuit pack is inserted or reset.
Yellow
Busy
The circuit pack is currently in use by the system.