Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
LED Interpretation 
7-5
SYSAM and Maintenance Circuit Pack LEDs 
7
The yellow LED displays various flashing patterns to provide status information 
useful in isolating faults in the fiber link and other components connected to the 
fiber link. 
Table 7-1
 illustrates the EI yellow LED states.
SYSAM and Maintenance 
Circuit Pack LEDs
TN1648 System Access-Maintenance (SYSAM) and TN775 EPN Maintenance 
circuit packs have seven LEDs on their front panels. The top three LEDs are the 
standard group of red, green and yellow, and indicate the status of the circuit 
pack. The green LED on TN775s blinks faintly once per second, indicating 
continual self-testing.
The second group of three LEDs, labeled “ALARMS”, reflect maintenance 
conditions throughout the system, and indicate alarms reported against other 
components, as shown in 
NOTE:
On systems with duplicated SPEs, disregard the Major, Minor, and Warning 
alarm LEDs on the standby SYSAM circuit pack. Only those on the active 
SYSAM (see yellow LED, third from the top) are updated with the current 
system status.
Table 7-1.
Expansion Interface Yellow Led Flashing Codes
LED on
LED off
Condition
0.1 sec
0.1 sec
Fiber Out-of-Frame. This state indicates a failure of test 
#989. This may be caused by absence of the opposite 
end EI or Switch Node Interface, a broken or missing 
fiber, or a missing lightwave transceiver on either 
endpoint.
0.5 sec
0.5 sec
In Frame 
 No Neighbor. This state corresponds to a 
failure of test # 237, usually due to a failure of this EI or 
of the EI or SNI at the other end of the fiber.
2 sec
0.2 sec
Expansion Interface Active. This is the normal state of 
an active EI that is an archangel of an Expansion Port 
Network.
solid on
Expansion Interface Active. This is the normal state for 
an active EI that is not an EPN archangel. These include 
EPN EIs connected to other EPN EIs in Direct Connect 
Configurations, and EIs located in the Processor Port 
Network.
solid off
Expansion Interface Standby. This is the normal state for 
a standby EI in systems with a duplication option.