LED Interpretation 
7-4
Expansion Interface Circuit Pack LEDs 
7
Misconnected optical fiber cables may cause several circuit packs to 
alarm.
Packet bus faults can cause several port circuit packs to display red 
LEDs.
If a circuit pack has had at least five minutes to be initialized, and the red LED is 
lit without an associated alarm in the Alarm Log, the circuit pack may not be in 
communication with the system. This may also be the case when a circuit pack is 
properly administered and present in its slot, but there is an error type 1 logged 
against it. To determine if this is so, proceed as follows:
Issue the list configuration board UUCSS command. If the system does 
not detect the circuit pack, this command will return
identifier not assigned
 
or
no board
.
If the documentation for the associated maintenance object gives no 
special instructions for this situation, go to the next step.
Check the Hardware Error Log for TONE-BD or TDM-BUS errors. Use the 
test tdm and test tone-clock commands and use the appropriate 
maintenance procedures to resolve any identified faults. If this does not 
resolve the problem, go to the next step
Reseat the suspect circuit pack.
!
CAUTION:
This procedure can cause a partial or total service outage. Consult 
thoroughly the documentation for the associated maintenance object 
before proceeding. Observe the precautions and procedures 
described above.
Inspect the backplane connectors for bent pins.
If the system seems to be functioning correctly, but the circuit pack in 
question will not communicate with the system, replace the circuit pack.
Expansion Interface Circuit Pack LEDs
The Expansion Interface (EI) TN570 circuit pack has the standard red, green and 
yellow LEDs. The red and green LEDs have the traditional meaning, where red 
indicates an alarm condition, and green indicates testing in progress.