Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-38
busyout cdr-link 
8
Output 
For the following output example, assume that the command, backup disk is 
entered on a duplex system.
busyout cdr-link
busyout cdr-link [primary | secondary]
The busyout cdr-link command puts a specified call detail recording link in a 
maintenance busy state. When busied out, the link is dropped and must be 
reestablished later when returned to service. See the description of status link 
for more information on links.
Parameters
Examples
busyout cdr-link
busy cdr secondary
For more information see the following sections at the beginning of this chapter: 
Busyout and Release Commands, Common Input Parameters, and Common 
Output Fields.
Processor
Identifies the processor carrier that was backed up (SPE-A, or 
SPE-B).
Command 
Completion Status
Results of the command, and the reason for any failure are 
displayed.
[primary | secondary]
This qualifier is used to specify one of the two possible links to 
CDR output devices. Primary is the default.
 
 backup disk
                               BACKUP DISK
 
 Processor Command Completion Status
 
 SPE-A      Success
 SPE-B      Success
 
 
 
 Command Successfully Completed