Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-40
busyout fiber-link 
8
This command puts a specified DS1 facility of a DS1C Complex into a 
maintenance busy state. Each DS1C complex uses from 1 to 4 DS1 facilities. 
One of the facilities, called the packet facility, carries the control channel for all 
facilities in the complex, all packet traffic, and some circuit connections. The 
other facilities carry circuit connections only. Whenever the circuit pack resets, 
the packet facility is set on the “a” facility. If system software detects a problem 
with this facility, it switches the packet and control traffic to another facility. The 
busyout command is not allowed on the packet facility unless the override 
qualifier is used. When the override is used, all packet and circuit traffic on the 
packet facility is switched to one of the other 3 facilities; all traffic that was on the 
destination facility before the switch is dropped. There is no way to tell which 
facility is carrying the packet and control traffic without attempting to busy it out
If there is only 1 facility left in service on the circuit pack, it cannot be busied out. 
In this case, the circuit pack must be busied.
!
CAUTION:
Busying out a non-packet facility disrupts all traffic carried on that facility. 
Use of the override command to busy the packet facility disrupts all traffic 
on the facility to which the packet and control traffic is moved. Which facility 
this is cannot be determined in advance.
On critical reliability systems (duplicated PNC) a facility on the active PNC 
cannot be busied out. To busyout a facility on the standby PNC, the standby PNC 
must first be busied out by busyout pnc.
busyout fiber-link
busyout fiber-link fiber# [a-pnc | b-pnc]
The busyout fiber-link command puts a specified fiber link into a maintenance 
busy state. (See Busyout and Release Commands at the beginning of this 
chapter). A fiber link is a connection carrying all circuit and packet traffic 
between two port networks, two switch nodes, or a port network and a switch 
node. A fiber link may contain a DS1 CONV complex used to provide 
connectivity to a remote EPN.
!
CAUTION:
On systems with simplex PNC, the busyout command is destructive. All 
calls and application links carried on the busied out fiber link will be torn 
down, and new calls will not be established over the link.
On systems with duplicated PNC, the command is allowed only on a fiber link on 
the standby PNC, does not impact service, and requires that the standby PNC be 
busied first.
For more information on fiber links, see FIBER-LNK in Chapter 9.