Maintenance Commands 
8-39
busyout data-module 
8
busyout data-module
busyout data-module extension
This command puts the specified data module in a maintenance busy state, 
whether or not it is installed. No call processing may be executed on the data 
modules or over the data channels. A list of all data-modules administered on the 
system can be displayed with list data-module. This form gives the extension, 
port, type and other data for each data-module. The following table gives the 
maintenance object name for each type of data-module listed in the “Type” field 
on the list data-module form.
busyout disk
busyout disk C
This command puts the hard disk drive of the Mass Storage System (MSS) into a 
maintenance busy state. Placing the disk in a busyout state prevents read and 
write access to the disk except when performed by demand maintenance 
testing. This command and the release command abort if any other MSS 
operation has already begun.
When the release command is issued, all alarms against the disk are 
automatically resolved. If the host-adapter is busied out, it must be released 
before the disk can be released. When the host-adapter becomes out-of-service 
due to test or reset failures and becomes uninstalled, the disk also becomes 
uninstalled, and all access by system software and maintenance tests and 
commands is blocked.
The cabinet is always 1 and need not be entered. The carrier, a or b, must be 
entered only on systems with duplicated SPEs.
busyout ds1-facility
busyout ds1-facility UUCSSf [override]
Type
Maintenance Object
adm-t
BRI-SET
announcement
DAT-LINE
dtdm
DIG-LINE
pdm
PDMODULE
system-port
DAT-LINE
x.25
PGATE-PT