Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-325
test alarms 
8
When errors are encountered preparing a particular object to be tested (not 
inserted, contention, etc.) the an error message will be displayed. This error 
message will be displayed in the TEST RESULTS data.
For the following output example, assume that only one alarm was in the alarm 
log and it is on the board in cabinet 1, carrier c, slot 7. The command that was 
entered was “test alarms” and the query form was left empty by just pressing 
ENTER
.
Feature Interactions
With the enhancement of multiple maintenance users, there may be a possibility 
of two users attempting to test the same physical hardware (e.g. one via the test 
alarms command and another through the test board command). If this 
command should attempt to test a board that is currently being tested by another 
user, a error message is displayed.
Alt. Name
The alternate means of identifying the maintenance object. This field 
contains the extension when the object is a station, and it contains 
xxx/yyy when the object is a trunk, where xxx is the trunk group number 
and yyy is the member number. It contains P/xxx when the object is a 
private CO line, where xxx is the private CO line group number.
Test No
The actual test that is being executed.
Result
An indicator as to whether the test failed, passed, aborted or no 
hardware was available (no board). If this field has conflict, this means 
that another user was testing this hardware. If this field has epn-down it 
means that the epn is inaccessible at this time.
Error Code
A numerical description of why the test failed or was aborted.
test alarms                                                            Page   1
                                 ALARM ENTRY
Port       Maintenance On   Alt     Alarm   Svc    Ack?  Date        Alarm
           Name        Brd? Name    Type    State  1 2   Alarmed     Count
01C03      UDS1-BD     n            WARNING              03/06/16:48 1/4
                                 TEST RESULTS
Port      Maintenance Name  Alt. Name Test No. Result            Error Code
01C03     UDS1-BD                     138      NO BOARD
01C03     UDS1-BD                     139      NO BOARD
01C03     UDS1-BD                     140      NO BOARD
01C03     UDS1-BD                     141      NO BOARD
01C03     UDS1-BD                     142      NO BOARD
01C03     UDS1-BD                     143      NO BOARD
01C03     UDS1-BD                     144      NO BOARD
01C03     UDS1-BD                     145      NO BOARD
01C03     UDS1-BD                     146      NO BOARD
Testing completed for this object.