Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-326
test analog-testcall
8
test analog-testcall
The test analog-testcall command causes the Automatic Transmission
Measurement System (ATMS) to originate a test calls over analog trunks. ATMS
collects performance measurements on the test call and compares them to
administered thresholds. Detail and summary reports of these measurements are
generated with the list testcalls command.
Measurement System (ATMS) to originate a test calls over analog trunks. ATMS
collects performance measurements on the test call and compares them to
administered thresholds. Detail and summary reports of these measurements are
generated with the list testcalls command.
You can specify testing of an entire trunk group or an individual trunk using either
group/member addresses or port and circuit pack location. The type of test call,
the number of the testing line on the far-end switch and various other parameters
must be administered on the trunk group form before the command can execute.
group/member addresses or port and circuit pack location. The type of test call,
the number of the testing line on the far-end switch and various other parameters
must be administered on the trunk group form before the command can execute.
ATMS, the operation of this command, and the measurement reports are
described in Automatic Transmission Measurement System (ATMS) in
described in Automatic Transmission Measurement System (ATMS) in
‘‘Additional Maintenance Procedures’’
.
test board
test board UUCSS [short | long] [repeat # | clear] [schedule]
The test board command will validate that the board exists at the specified
location. Based on the logical type (e.g., Analog, Digital, Hybrid, etc.) of board a
series of tests will be executed. Each individual test will exercise diagnostics on
the board and then return results of the test along with any possible error codes.
location. Based on the logical type (e.g., Analog, Digital, Hybrid, etc.) of board a
series of tests will be executed. Each individual test will exercise diagnostics on
the board and then return results of the test along with any possible error codes.
Destructive long tests on a Switch Node Interface (SNI) board are not allowed
unless the board has been busied out.
unless the board has been busied out.
For more information see Common Input Parameters and Common Output Fields
at the beginning of this chapter.
at the beginning of this chapter.
test analog-testcall
trunk group# / member# | port UUCSSpp | board UUCSS
[full | supervision | no-selftest | no-return-loss | no-st-or-rl]
[repeat #] [schedule]
[full | supervision | no-selftest | no-return-loss | no-st-or-rl]
[repeat #] [schedule]