Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-327
test cdr-link 
8
The following display shows a typical result when test board 1D07 is entered 
and slot 1D07 hods a Digital Line circuit pack with 7 ports administered.
test cdr-link
The test cdr-link command validates that a call detail recording link has been 
administered and established.
Parameters
For more information see 
 at the beginning of this chapter.
test customer-alarm
test customer-alarm UUC [short | long] [repeat # | clear] [schedule]
test cdr-link
primary | secondary
[short | long] [repeat number | clear] [schedule]
[primary | secondary]
A system may have up to two CDR links: a primary that is 
normally used and a secondary that serves as a backup in 
case the primary fails. This qualifier specifies which link to test. 
Primary is the default.
 
 test board 1d07 short                                       SPE B
 
                              TEST RESULTS
 
 Port      Maintenance Name  Alt. Name Test No. Result  Error Code
 
 01D07     DIG-BD                      52       PASS
 01D0701   DIG-LINE          5401      16       PASS
 01D0701   DIG-LINE          5401      17       PASS
 01D0702   PDMODULE          5460      17       PASS
 01D0703   PDMODULE          5461      17       ABORT       5
 01D0704   PDMODULE          5444      17       ABORT       5
 01D0705   DIG-LINE                    16       ABORT       1392
 01D0705   DIG-LINE                    17       ABORT       1392
 01D0706   DIG-LINE          Attd2     16       PASS
 01D0706   DIG-LINE          Attd2     17       PASS
 01D0707   DIG-LINE          Attd1     16       PASS
 01D0707   DIG-LINE          Attd1     17       PASS
 
 Command Successfully Completed