DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-229
ATM PNC-DUP (ATM PNC Duplication) 
9
unrefresh of those connections that utilize the faulted component(s) is performed. 
If the health of the standby PNC improves, a selective refresh of connections on 
the affected route is performed so that call setup is consistent between the active 
PNC and the healthy parts of the standby PNC.
The 
Standby Refreshed?
 field on the status pnc screen does 
not refer to the 
selective type of refresh. It refers only to a global refresh that is performed when:
The system is initialized and PNC duplication is enabled.
There has been a spontaneous PNC interchange.
The standby PNC has been released from busy-out.
A system reset of level 2 or higher has taken place.
The refreshed field may display yes when in fact the standby is partially 
unrefreshed. An interchange into an incompletely refreshed standby results in 
dropped calls. This can happen when a more severe fault occurs on the active 
PNC or when reset pnc interchange is used with the override option.
PNC interchanges
PNC spontaneous interchanges occur when PNC duplication software 
determines that the State of Health (SOH) of the standby PNC is better than that 
of the active PNC. 
PNC-DUP executes a spontaneous interchange in response to a message 
from a PNC component maintenance object indicating that either a fault 
has occurred on the active PNC or a fault has been resolved on the 
standby PNC. 
The PNC SOH is compared to the standby PNC, and an interchange 
occurs if the state of health of the standby PNC is now better than that of 
the active PNC.
A corresponding Major or Minor alarm is logged by the reporting MO, 
stimulating an alarm report.
When the resolution of a fault on the standby renders it more healthy than a 
simultaneously-faulted active PNC, the error message indicates the type and 
location of the 
improved component.
Once the interchange completes, the failed component is on the standby PNC. A 
demand interchange can be requested in the presence or absence of standby 
PNC faults. The following sequence of actions can be observed during a 
fault-free interchange:
1. The ATM-Expansion Interfaces currently acting as archangels in the EPNs 
are deactivated as indicated by the yellow LEDs going from flashing to on 
solid.