Configuring Individual WAN Connections
Configuring terminal-server connections
MAX 6000/3000 Network Configuration Guide
 4-79
Ethernet
Connections
joshua
Station=joshua
Active=Yes
Encaps=PPP
Encaps Options
Recv PW=localpw
The following example includes optional parameters for bringing down the terminal-server 
connection after a specified amount of idle time:
Ethernet
Connections
catherine
Station=catherine
Active=Yes
Encaps=PPP
Encaps Options
Recv PW=localpw
Session Options
TS Idle Mode=Input/Output
TS Idle=60
V.120 terminal-adapter connections
V.120 terminal adapters (also known as ISDN modems) are asynchronous devices that use 
CCITT V.120 encapsulation. The values that work best for V.120 operation are:
Maximum information field size for send and receive packets=260 bytes.
Maximum number of retransmissions (N200) =3.
Logical link ID (LLI)=256.
Idle timer (T203)=30 seconds.
Maximum number of outstanding frames=7.
Modulo=128.
Retransmission timer (T200)=1.5 seconds.
Types of frames accepted=UI, I. (I-type frames are recommended.).
Call placement: The MAX unit can receive V.120 calls, but cannot place them..
Note:
If the connection uses PAP or CHAP authentication, the ISDN terminal adapter should 
be configured for async-to-sync conversion. In this case, V.120 encapsulation is not required in 
the Connection profile. For more information, see “Connection authentication issues” on 
page 4-78.
The V.120 device must be correctly configured to place calls to the unit. The settings required 
for compatible operation of a V.120 device and the unit are listed below. For information about 
entering these settings, see the V.120 manual.
V.120 maximum transmit frame size=260 bytes.