Siemens PANEL PC 877 User Manual

Page of 288
Technical data 
 
15.1 General technical data 
 
SIMATIC Panel PC 877 
15-6
 
Operating instructions, Release 07/2006, A5E00877780-01 
General technical data 
Safety 
Protection class 
Protection class I to IEC 60536, i.e.: Device with PE ground terminal 
Standards 
IEC 60950-1, EN 60950-1, DIN EN 60950-1, EN 61131-2 
Approvals 
AC device: cULus in accordance with UL 60950-1 
DC device: cULus in accordance with UL 508  
Conformity 
CE 
With clamp attachment, encircling seal and pressed-on plastic cap for 
USB interface
 5)
 
IP 65, NEMA 4 
Degree of protection 
With screw attachment 
IP 54 
Liability of product 
nonconformance 
24 months 
Quality assurance 
to ISO 9001 
 
1) Limitations for optical drives:  
Burner operation is only allowed without external disruptions and at an ambient temperature 
between +5° C and +40° C.  
2) Limitation for optical drives:  
 10 to 58 Hz: 0.019 mm / 58 to 500 Hz: 2.5 m/s
2
 approx. 1/4 g. Burner operation is only 
allowed without external disruptions. 
3) Electrically isolated within the safety extra-low voltage circuit, SELV. 
4) A small number of faults in the display is unavoidable. However, the displays do comply 
with the described quality standards of the ISO stanard 13406-2, class 2. 
 
Bad pixels 
Permissible number  
Permanently bright and permanently dark pixels 
≤ 12 
Permanently bright, green pixels 
≤ 5 
5) The front USB interface cannot be used in some device variants. 
6) USB 2.0 standard.