Technical data 
 
15.1 General technical data 
SIMATIC Panel PC 877 
Operating instructions, Release 07/2006, A5E00877780-01 
15-7
 
Permissible temperature ranges depending on the installation method 
 
Panel PC 877 
Complete unit 
Internal cabinet 
temperature 
Ambient 
temperature 
cabinet 
Comment 
Installed in cabinet  
different temperatures 
50 °C 
40 °C 
1)4) 
Installed in cabinet  
Same temperature inside and outside 
45 °C 
45 °C 
2)4) 
Computer unit and control unit separated, 
using Remote Kit 
12" control unit 
15" control unit 
19" v 
Computer unit, Intel ® Pentium 4 Mobile 
2.2 GHz, 400 MHz 
 
 
50 °C 
50 °C 
50 °C 
55 °C 
 
 
45 °C 
45 °C 
45 °C 
 
 
 
 
5) 
3)4) 
These values are applicable for vertical installation and when air is flowing through the 
cabinet. 
1) Max. PCI load 50 W 
2) Full expansion, max. PCI load 75 W (5 slots) 
3) PCI modules are not permitted 
4) Above 40 °C, optical drives must not be operated 
5) When the 19" front is operated at ambient temperatures between 45 °C and 50 °C, the 
USB interface of the Remote Kit (rear USB interface) must not be used.